background image

Summary of Contents for C742G

Page 1: ......

Page 2: ...laced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sho...

Page 3: ... the control knobs are in the closed position when not in use When using other electrical appliances ensure the cable does not come into contact with the hot surfaces of the cooking appliance Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage Never leave the hob unattended when cooking with oil and fats Never use plastic or alumin...

Page 4: ... burner efficiency you had better use pots and pans with a flat bottom fitting the size of the burner used see table Burner Minimum Diameter Maximum diameter Wok Large rapid Medium semi rapid Small auxiliary 240mm 180 mm 120 mm 80 mm 260mm 260 mm 220 mm 160 mm If you using a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle...

Page 5: ...orrective action Check that the unit is plugged in and the electrical supply is switched on Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly e g after cleaning The gas ring burns unevenly Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning Instr...

Page 6: ...in a room of volume between 5m and 10m an air vent of effective area of 50cm is required while if the volume exceeds 11m no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5m and 11m 3 If there are other fuel burning appliances in the same room which should be consulted to determine the requisite air vent...

Page 7: ...tely Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to RC 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Ensure that the main connection pipe does not exert any strain on the hob When a...

Page 8: ...port and front left burner cap and crown Fit manometer tube over the injector Turn on the burner gas supply and ignite another burner Turn off the burner supplies Conversion form NG to LPG or from LPG to NG Important The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with which gas category Please ch...

Page 9: ...9 Figure 3 Figure 4 Figure5 Figure6 Figure7 Figure8 ...