Gas hoses designed for natural gas MUST NOT be used for
supplying LPG gas (LPG gas hoses can be identified by a either a red band
or stripe on the rubber outer coating of the hose).
•
The hose should not be crushed or trapped or be in contact with
sharp or abrasive edges.
Using a suitable leak detection fluid solution check each gas connection one
at a time by brushing/Spraying the solution over the connection.
The presence of bubbles will indicate a leak.
If there is a leak, tighten the fitting and then recheck for leaks.
NOTE: It is mandatory to install a isolation valve to allow the gas supply to
be opened and closed. Install the isolation valve between the gas supply line
to the relevant room and the appliance. Ensure that there is unhindered
access to
this valve. Once the gas line is connected, check for leaks in the
connections using
a leak detector fluid or sniffer
. Switch the appliance on
as described in the instruction manual. Light all the burners and check that
the flames remain stable at both the high and low settings.
Converting the gas type
If the appliance is not already set to use the type of gas that is available, the
appliance must be converted.
Conversion to a different type of gas must be carried out by an authorised
expert and in accordance with the applicable regulations.
The rating plate indicates the type of gas and the gas pressure which have
been pre-set in the factory.
In order to convert to a different type of gas, the nozzles must be replaced and
the low flame must be adjusted.
Oven burner Replacing the nozzles Proceed as follows:
• Dismantle the shelf part of the oven.
• Loosen the screw on the front part of the oven burner and pull it upwards
slightly.
CONVERTING THE GAS TYPE
8