5
1 - Electrical Installation - Wall box connection
This appliance must be connected to a
double pole isolating switch (fig. 1.1) and
to the terminal block in the cooker (figs.
1.2 & 1.3) using the following guide:
FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 13 AMP FUSE
ON
Fig. 1.1
1) The wire which is coloured brown
must be connected to the terminal
marked L (Live), or coloured Red.
2) The wire which is coloured blue must
be connected to the terminal marked
N (Neutral), or coloured Black.
3) The wire which is coloured green and
yellow must be connected to the ter-
minal marked E (Earth) or
coloured Green.
IMPORTANT: These connections must
be carried out by a qualified electrical
engineer.
Fig. 1.2
Fig. 1.3