CONVERSION TO A DIFFERENT TYPE OF GAS
Before converting the appliance for operation with a different gas type, check which type of gas it
is currently set to operate with (adhesive label (picture) on appliance). Disconnect the electrical
power supply to the appliance; For the correct nozzle diameter, refer to the relative table in this
booklet.
Replacing the lower burner nozzle
1) Remove the burner cover plate (see REMOVAL OF THE BURNER COVER PLATE).
2) Remove the screw securing the oven burner and withdraw the burner from the support together
with the heat sensor and the ignition spark plug.
3) Remove the nozzle using a 7 mm box wrench
4) Screw the new nozzle in fully (diameter in hundredths of millimetre stamped on the nozzle),
taking care not to cross the thread.
5) Replace the burner reversing the operations in step 2 above.
6) Replace the cover plate.
7) Adjusting the minimum flame (see instructions)
NOZZLE TABLE
The diameters in hundredths of millimetre are stamped on the nozzle.
Burner
kW
rated load
Ø Nozzle bore in mm
G20
20 mbar
G30
50 mbar
G30
29 mbar
Oven burner
2,50
1,13
0,67
0,76
Grill burner
2,20
1,12
0,65
0,75