background image

9

7

built in clearances:

GENERAL:

The PSQSB2000 Side Burner is designed for easy 
placement into non-combustible masonry enclosures.  
For non-combustible applications the grill drops into the 
opening and hangs from its side flanges.  A deck is not 
required to support it from the bottom. 

Please review the detail drawing shown and take into 
account the provisions shown for gas line hook-up 
clearances in the right rear corner.  It is recommended 
that ventilation holes are provided in the enclosure in the 
event of a gas leak.  The supporting ledges or deck must 
be level and flat.  The counter should also be level. 

4 x 4 opening for 
manifold intake 
pipe

A

B

C

A - width = 11-1/8"

B - height = 8-3/4"

C - depth = 24-3/4"

KEY:

LOCATION:

When determining a suitable location, take into 
account concerns such as exposure to wind, 
proximity to traffic paths, and keeping any gas or 
electrical supply lines as short as possible.  
Locate the grill only in a well-ventilated area.  
Never locate the grill in a building, garage, 
breezeway, shed or other such enclosed areas 
without an approved ventilation system.  During 
heavy use, the grill will produce a lot of smoke.  
Ensure there is adequate area for it to dissipate.  

IMPORTANT:
A minimum of 6" clearance from the sides and 
back must be maintained from the side burner 
above and 1" below the cooking surface to 
combustible construction.

8

Summary of Contents for Performance Series PSQSB2000

Page 1: ...U S E A N D C A R E G U I D E P E R F O R M A N C E S E R I E S S I D E B U R N E R S THE POWER OF PERFORMANCE TM...

Page 2: ...s NAT LP 5 6 Leak Testing 7 Built In Clearances 8 Replacing Regulators and Hose 9 Lighting Instructions 10 Care and Cleaning 11 Troubleshooting 12 Installer s Final Checklist 13 We re here for you 14...

Page 3: ...de ourselves on superior customer service and work harder to respond to your needs quickly and effectively Our Customer Service representatives are here to assist you and are just a phone call away Yo...

Page 4: ...Do not try lighting this appliance without reading the Lighting Instructions section in this manual Improper installation adjustment alteration service or maintenance can cause property damage injury...

Page 5: ...burner NEVER let clothing pot holders or other flammable materials come into contact with or come too close to any grate burner or hot surface until it has cooled Fabric may ignite and result in pers...

Page 6: ...the gas supply shut off valve is located so that you know where to shut off the gas to the grill IF YOU SMELL GAS your installer has not done a proper job of checking for leaks If the connections are...

Page 7: ...from open edges of the unit to avoid burns associated with unintentional spillovers Hold the handle of the pan to prevent movements of the utensil when turning or stirring food For proper lighting and...

Page 8: ...s in excess of 1 2 PSIG 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping sy...

Page 9: ...tem to purge before attempting to light the burners NOTE Side Burner uses the LP regulator from adjoining grill LP TANK REQUIREMENTS A dented or rusty LP tank may be hazardous and should be checked by...

Page 10: ...o the unit They are located at the bottom left and right hand corners of the front fascia Using a screwdriver remove the screws Lastly gently pull the panel downward and out making sure that you do no...

Page 11: ...t The counter should also be level 4 x 4 opening for manifold intake pipe A B C A width 11 1 8 B height 8 3 4 C depth 24 3 4 KEY LOCATION When determining a suitable location take into account concern...

Page 12: ...LP is there gas in the tank Always keep your face and body as far away as possible from the Side Burner when lighting DO NOT leave the side burner unattended while cooking KEEP a spray bottle of soap...

Page 13: ...iron for maximum durability The side burner cover protects the Side Burners from dust and debris and also acts as a work surface When using the grill burners with the Side Burner cover in place be ca...

Page 14: ...ust are allowed to collect over time the presence of these materials can seriously jeopardize burner performance It will be necessary to clean out the burner ports using a thin wire needle or straight...

Page 15: ...ld see a spark jump from the tip of the ignition when the ignition is pushed If there is no spark when ignition button is pushed check the battery condition Battery condition should be checked at leas...

Page 16: ...l or 10 W C LP gas All Internal Packaging Removed Manual Shut Off Valve Installed and Accessible Knobs Turn Freely and Bezels Centered Unit Tested and Free of Leaks Each Burner Lights Individually Ign...

Page 17: ...prings CA 90670 USA Fax us at 562 903 1167 Email us at customerservice capital cooking com FOR ________________________________________________________________________ MODEL __________________________...

Page 18: ...ns or liability in connection with the sale of this appliance WILL NOT PAY FOR Installation or start up Shipping damage Service by an unauthorized agency Damage or repairs due to service performed by...

Reviews: