9
7
built in clearances:
GENERAL:
The PSQSB2000 Side Burner is designed for easy
placement into non-combustible masonry enclosures.
For non-combustible applications the grill drops into the
opening and hangs from its side flanges. A deck is not
required to support it from the bottom.
Please review the detail drawing shown and take into
account the provisions shown for gas line hook-up
clearances in the right rear corner. It is recommended
that ventilation holes are provided in the enclosure in the
event of a gas leak. The supporting ledges or deck must
be level and flat. The counter should also be level.
4 x 4 opening for
manifold intake
pipe
A
B
C
A - width = 11-1/8"
B - height = 8-3/4"
C - depth = 24-3/4"
KEY:
LOCATION:
When determining a suitable location, take into
account concerns such as exposure to wind,
proximity to traffic paths, and keeping any gas or
electrical supply lines as short as possible.
Locate the grill only in a well-ventilated area.
Never locate the grill in a building, garage,
breezeway, shed or other such enclosed areas
without an approved ventilation system. During
heavy use, the grill will produce a lot of smoke.
Ensure there is adequate area for it to dissipate.
IMPORTANT:
A minimum of 6" clearance from the sides and
back must be maintained from the side burner
above and 1" below the cooking surface to
combustible construction.