17

Contour 5W Dimensions

All dimensions shown are in mm

Contour 

Log Store

5kW

Model

CONTOUR5LW

A

1050mm

B

125mm

C

300mm

D

675mm

E

420mm

F

470mm

G

150mm

H

420mm

Contour 

Pedestal

5kW

Model

CONTOUR5PW

A

1050mm

B

125mm

C

300mm

D

800mm

E

500mm

F

420mm

G

470mm

H

195mm

I

240mm

J

150mm

K

420mm

Contour 

Midi

5kW

Model

CONTOUR5MW

A

850mm

B

125mm

C

300mm

D

675mm

E

460mm

F

420mm

G

470mm

H

420mm

I

150mm

Installation Instructions

Summary of Contents for CONTOUR Window Series

Page 1: ...The CONTOUR Window Series CONTOUR5MW CONTOUR5PW CONTOUR5LW Manual Operation Installation www capitalfireplaces co uk ...

Page 2: ...d the paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a result of improper curing or misuse of the stove such as over fuelling or running the stove too hot Therefore any peeling is not covered by your warranty NOTE During the final higher temperature burn...

Page 3: ...eway Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire Surround 15 Flue Connection 16 Connecting The Flue 16 On Delivery Of The Stove 16 After Installation 16 Contour 5W Dimensions 17 Contour 5W Parts List 18 Maintenance 19 Warranty Guarantee 20 DEFRA R...

Page 4: ...8 Version 2 8 WOOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500mm SIDE AVERAGE FLUE GAS TEMPERATURE 231o C 174o C Manufacturer s Declaration The stove has been type tested by BSRIA Ltd and fulfils the applicable rules for EN 13240 2001 CE marking Ma...

Page 5: ...N NUMBER INSTALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the function and safety of the stove we recommend that the installation must be carried out by an authorised technician Contact one of our dealers to find a suitable fitter Structural Support C...

Page 6: ... wood to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the fire Peat Cut peat must be dried before using in the stove in order to reduce the amount of tar deposits produced You should burn Peat in the same way as wood fuel on a bed of ash at the base of...

Page 7: ...s a balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is delivered to the clean glass air wash down the front of the glass and the Eco Cleanburn afterburn at the rear of the fire box However solid mineral fuels burn from the bottom up so you require air flo...

Page 8: ...long with the kindling on the base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before closing the door pull the Air Wash control towards you to open the rear Air Wash vent see Fig 2b Allow the fire to be fully ignited before adjusting the air vents to the pre...

Page 9: ...for long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and primary and riddle bar will heat up when the fire is lit and running But when you need to touch them to adjust or reload the fire you must wear gloves Therefore to avoid injury please wear appropriate han...

Page 10: ...is very important to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allowing excess ash to drop through to the ashpan below the firebox see Fig 4 Be sure not to completely empty the base of ash It is very important that all ash is cool before attempting to...

Page 11: ... the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cannot be blocked Seasonal Use If the stove is not used for a long period of time e g Summer then it must be thoroughly cleaned with ash and unburned fuel being removed It is important to leave air controls fully open when ...

Page 12: ... glass still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and not affected by down draught When certain smokeless fuels you may notice some blackening of the glass below the grill level this is to be expected and shouldn t obscure your view of the fire or aff...

Page 13: ... stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after closing all the vents and door then you must contact the fire brigade immediately do not attempt to fight the fire yourself After any chimney fire your chimney should be carefully examined for damage before you attem...

Page 14: ...rance around the stove to glass excluding hearths Please note the Hot Zone to the front of the stove extends 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Operating Instructions Fixing Points If you would like to fix the stove to the ground you can do this using the fixing points shown below For a...

Page 15: ... the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet of the stove body to the very top of the chimney The outlet on our stove is 5 inches in diameter therefore your chimney must have a minimum width of 5 inches but preferably be 7 8 inches wide Your chimney can be either square or circular ...

Page 16: ...e conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be sealed with fire cement and all flue connections must be well sealed Any horizontal sections of flue must not be longer than 150mm With most flue connections your installer should fit a soot door in your chimney to allow access to sweep i...

Page 17: ...CONTOUR5LW A 1050mm B 125mm C 300mm D 675mm E 420mm F 470mm G 150mm H 420mm Contour Pedestal 5kW Model CONTOUR5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Contour Midi 5kW Model CONTOUR5MW A 850mm B 125mm C 300mm D 675mm E 460mm F 420mm G 470mm H 420mm I 150mm Installation Instructions ...

Page 18: ...Contour 5W Series Manual Capital Fireplaces 2018 18 Installation Instructions CONTOUR Parts List ...

Page 19: ...Brick Removal 1 Remove the two screws holding the rear boards in place the two rear fireboards can be removed by pulling out from the middle 2 Remove both Side Bolts from inside the firebox to free the top of the Side Fireboards remove these carefully as they are very fragile 3 Lift the Top Fireboard up to slide it off its retainers and remove 4 Remove the Retaining Plate by pulling towards you to...

Page 20: ...ended Warranty that your Capital Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent in other countries Records and receipts of annual services will be required in the event of a warranty claim during the period of the extended warranty This warranty is not transferable and is extended only to and solely f...

Page 21: ...elivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of the original warranty period If you should ever wish to make a warranty claim because of a product fault or defect you must inform your retailer within a reasonable amount of time this is within 14 days from the date on which the...

Page 22: ...State or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements Recommend Fuels for use in a Designate...

Page 23: ...W N A ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 60 A 40 A 20 OAK STOVES Contour Log Store Clean Burn Stove A I II A A B C D E F G 2015 1186 4 9 kW N A ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 60 A 40 A 20 OAK STOVES Contour Pedestal Clean Burn Stove A I II A A B C D E F G 2015 1186 4 9 kW N A ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY EN...

Page 24: ...www capitalfireplaces co uk Oak Stoves Unit 11 Village Farm Industrial Estate Village Farm Road Pyle Bridgend CF33 6BL ...

Reviews: