Caratteristiche Tecniche

Alimentazione

13 Vdc ± 10% ottenuta da controllo 
ACU; assorbimento 250 mA max. 
Alimentazione raccomandata per il 

controllo collegato: SELV o PELV

Cavo di collegamento al 

controllo:

 

Lunghezza max: 10 m (dispositivo da 
incorporare)  Sezione: AWG: 26

Buzzer

disponibile in tutti i modelli

Sensore di temperatura:

 

incoporato

Contenitore

Materia plastica in policarbonato

Dimensioni:

 

vedere figure

Montaggio:

A pannello

Display: 

LED 2 righe, punto decimale e icone 
polifunzionali

Condizioni ambientali 

funzionamento: 

-20T60 ˚C, <90% U.R. non 
condensante

Condizioni ambientali 

immagazzinamento

-40T85 ˚C, <90% U.R. non 
condensante

Connettività NFC: 

Max distanza 10mm, variabile 
secondo il dispositivo mobile 
utilizzato

Connettività BLE: 

Max distanza 10m, variabile secondo 
il dispositivo mobile utilizzato

Grado di protezione:

 IP65 sul frontale, IP20 sul retro

Grado Inquinamento 

ambientale:

 

--

Temp. per la prova con la sfera: 

125°C

Tensione di impulso nominale: 

0.8 kV

Tipo di azione e disconnessione: 

1.Y

Costruzione del dispositivo di 

comando:

dispositivo da incorporare

Classificazione secondo la 

protezione contro le scosse 

elettriche:

Incorporabile in apparecchi di classe 
I o II

Interfaccia seriale:

 

Modbus su RS485

Classe e struttura del software: 

Classe A

Pulizia frontale: 

Utilizzare esclusivamente un panno 
morbido e non abrasivo e detergenti 
neutri o acqua

Certificazioni: 

CE, UL

Sicurezza elettrica:

EN60335-1, UL60335-1, EN60730-1, 
UL60730-1

Compatibilità elettromagnetica: 

EN61000-6,EN61000-3, EN55014-1, 
EN61000-4

Display (Fig. 7)

Icona Funzione

Accesa

Lampeggiante

Pompa Impianto

Pompa Impianto 
attiva

Pompa Impianto 
in funzionamento 
manuale

Stato Dispositivi 
Sorgente (pompa/
ventilatore) 

Dispositivi 
sorgente attivo

Dispositivo 
sorgente in 
funzionamento 
manuale

Stato Compressori Compressori attivi Compressore in 

funzionamento 
manuale (con EXV)

Resistenza 
Antigelo

Resist. Antigelo 
attiva

-

Modalità  
funzionamento

Riscaldamento

-

Raffrescamento

Allarme Alta 
Temperatura acqua

Defrost

Sgocciolamento 
dopo Defrost

Free-cooling 

-

Assistenza

Richiesta 
assistenza causa 
superamento 
soglia ore di 
funzionam.

Allarme grave, 
richiesto intervento 
personale 
qualificato

Tastiera

Tasto

Funzione

 

UP

Durante navigazione: permette di accedere al 
parametro precedente.
Durante impostazione param.: Incremento valore 
visualizzato.

DOWN

Durante navigazione: permette di accedere al 
parametro successivo.
Durante impostazione param.: Decremento valore 
visualizzato.

MAIN MENU:

Pressione breve: visualizzazione sinottico macchina
Pressione prolungata (3s): accesso parametri profilo 
user (set point, unità on-off,…)

 

Alarm

Pressione breve: visualizzaz. allarmi attivi e tacitazione 
buzzer. Pressione prolungata (3 s): reset allarmi.

 

PRG

Durante navigazione: permette di accedere al menù 
di parametrizzazione
Durante impostazione paramento
Pressione breve: Conferma il valore del parametro in 
modifica.
Pressione prolungata (3s): permette di tornare menu 
principale

Technical specifications

Power supply:

13 Vdc ± 10% supplied by ACU 

controller; max current 250 mA. 

Power supply recommended for the 

connected controller: SELV or PELV

Controller connection 

cable

Max length: 10 m (device to be 

incorporated) Size: AWG: 26

Buzzer

Available on all models

Temperature sensor

Built-in

Casing

Polycarbonate material

Dimensions:

 

see figures

Mounting:

Panel mounting

Display: 

LED 2 rows, decimal point, and multi-

function icons

Ambient operating conditions: 

-20T60 ˚C, <90% U.R. non-

condensing

Ambient storage conditions

-40T85 ˚C, <90% U.R. non-

condensing

NFC:

Max distance 10 mm, variable 

according to the mobile device used

BLE: 

Max distance 10 mm, variable 

according to the mobile device used

Protection index:

P65 at front, IP20 at rear

Environmental pollution:

3

Ball pressure test:

125°C

Rated impulse voltage:

0.8 kV

Type of action and 

disconnection:

1.Y

Construction of the control 

device

Device to be incorporated

Classification according to 

protection against electric shock

To be incorporated in class 1 or 2 

appliances

Serial interface

Modbus over RS485

Software class and structure

Class A

Cleaning the front side

Only use a soft, non-abrasive cloth 

and neutral detergents or water

Certifications

CE, UL

Electrical safety:

EN60335-1, UL60335-1, EN60730-1, 

UL60730-1

Electromagnetic compatibility:

EN61000-6,EN61000-3, EN55014-1, 

EN61000-4

Display (Fig. 7)

Icons Function

ON

Flashing

System pump

System pump 
active

System pump in 
manual operation

Source device 
status (pump/fan) 

Source devices 
active

Source device in 
manual operation

Compressor status Compressors ON Compressor in 

manual operation 
(with EXV)

Frost protection 
heater

Frost heater 
active

-

Operating mode

Heating

-

Cooling

High water 
temperature alarm

Defrost

Dripping after 
Defrost

Free cooling 

-

Service

Service request 
on exceeding 
operating hours

Serious alarm, 
action required by 
qualified personnel

Keypad

Key

Function

 

UP

During navigation: access the previous parameter.
During parameter setting: increase value displayed.

DOWN

During navigation: access the next parameter.
During parameter setting: decrease value displayed.

MAIN MENU:

Pressed briefly: unit overview display
Pressed and held (3 s): access user profile parameters 
(set point, unit on-off, ...)

 

Alarm

Pressed briefly: display active alarms and mute 
buzzer. Pressed and held (3 s): reset alarms.

 

PRG

During navigation: access the parameter menu
During parameter setting
Pressed briefly: confirm the value of the parameter 
being set.
Pressed and held (3 s): return to the main menu

NO POWER 

& SIGNAL 

CABLES 

TOGETHER

READ CAREFULLY IN THE TEXT!

Always keep the signal cables 

 and power cable in separate conduits.

AVVERTENZA

Questo prodotto va incorporato e/o integrato in un apparecchio o macchina finale. La verifica di conformità 
alle leggi e alle normative tecniche vigenti nel Paese in cui l’apparecchio o la macchina finale verranno 
utilizzati è responsabilità del costruttore stesso. Prima della consegna del prodotto, Carel ha già effettuato le 
verifiche e i test previsti dalle direttive Europee e relative norme armonizzate, utilizzando un setup di prova 
tipico, da intendersi non rappresentativo di tutte le condizioni di installazione finale.

WARNINGS

This product is to be integrated and/or incorporated into the final apparatus or equipment. Verification 

of conformity to the laws and technical standards in force in the country where the final apparatus or 

equipment will be operated is the manufacturer’s responsibility. Before delivering the product, Carel has 

already completed the checks and tests required by the relevant European directives and harmonised 

standards, using a typical test setup, which however cannot be considered as representing all possible 

conditions of the final installation.

IMPORTANT WARNINGS

The CAREL product is a state-of-the-art product, whose operation is specified in the technical 

documentation supplied with the product or can be downloaded, even prior to purchase, from the 

website www.carel.com.  -  The client (builder, developer or installer of the final equipment) assumes 

every responsibility and risk relating to the phase of configuration the product in order to reach the 

expected results in relation to the specific final installation and/or equipment. The lack of such phase 

of study, which is requested/indicated in the user manual, can cause the final product to malfunction 

of which CAREL can not be held responsible. The final client must use the product only in the manner 

described in the documentation related to the product itself. The liability of CAREL in relation to its own 

product is regulated by CAREL’s general contract conditions edited on the website www.carel.com and/
or by specific agreements with clients.

Disposal of the product

The appliance (or the product) must be disposed of separately in compliance with the 

local standards in force on waste disposal.

Reviews: