background image

 

 
L-L 265.00-BM 

20 / 24 

 

TECHNICAL SPECIFICATIONS 

JUMBO 800 

Burner Model 

 

RIELLO R40-N900S 

Burner Nozzle 

 

RIELLO G20 

Nominal Heat Input 

[BTU/h] 

800,000 

Natural gas 

  

Supply pressure 

[in w.c.] 

min 7" w.c. 

max 10" w.c. 

Normal 

altitude 0 - 

2.000 ft above 

sea level 

(U.S.A. and 

Canada) 

Heat  input  

[BTU/h] 

802,180 

Manifold pressure 

[in w.c.] 

2.68 

Burner head position 

[N°] 

Burner Air setting 

[N°] 

5.2 

Fuel consumption 

[CFH] 

772.0 

Altitude 2.000 

- 4.500 ft 

above sea 

level  (Canada 

only) 

Heat  input  

[BTU/h] 

721,962 

Manifold pressure 

[in w.c.] 

2.56 

Burner head position 

[N°] 

Burner Air setting 

[N°] 

Max 

Fuel consumption 

[CFH] 

694.80 

L.P.G. 

 

Supply pressure 

[in w.c.] 

min 8" w.c. 

max 13" w.c. 

 

Gas firing valve 

[in] 

0.464 

Normal 

altitude 0 - 

2.000 ft above 

sea level 

(U.S.A. and 

Canada) 

Heat  input  

[BTU/h] 

805,499 

Manifold pressure 

[in w.c.] 

2.20 

Burner head position 

[N°] 

Burner Air setting 

[N°] 

5.2 

Fuel consumption 

[CFH] 

317.16 

Altitude 2.000 

- 4.500 ft 

above sea 

level  (Canada 

only) 

Heat  input  

[BTU/h] 

724,950 

Manifold pressure 

[in w.c.] 

2.00 

Burner head position 

[N°] 

Burner Air setting 

[N°] 

Max 

Fuel consumption 

[CFH] 

285.44 

Air flow 

[cfm] 10,005.8 

Fan Thermostat Setting 

[°F] 

95 

Burner Thermostat Setting 

[°F] 

194 

Power supply   

Phase  

 

Voltage [V] 

 

 

240 

Frequency   

[Hz] 

60 

Electric consumption 

[W] 3,300 

[A] 15.5 

Flue diameter 

[in] 

7.87 

Compulsory flue draft 

[in] 

0.05 

Maximum air temperature 

[°F] 

250 

Max. operating pressure elec. gas valve 

[psi] 

Air distribution duct 

Max Static pressure 

[in] 

0.80 

Max length 1 way  - dia 28”/26" 

[ft] 

90 

Max length 2 ways  - dia 24" 

[ft] 

45 

Max length 4 way  - dia 18" 

[ft] 

45 

Max length 5 way  - dia 14" 

[ft] 

36 

Inlet flexible duct 

Max length 1 way  - dia 28.8" 

[ft] 

18 

Noise level at  1 m 

[dBA] 

71 

Dimensions. L x W x H  

[in] 

91.93 x 38.98 x 62.34 

Weight 

[lb] 773.82 

 

 

Summary of Contents for JUMBO 400

Page 1: ...L L 265 00 BM 1 24 INSTRUCTIONS MANUAL MANUEL D INSTRUCTIONS SPACE HEATER GENERATEUR D AIR CHAUD JUMBO 400 JUMBO 600 JUMBO 800 FR EN...

Page 2: ...ING MATERIALS PAPER OR CARDBOARD AT SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PR...

Page 3: ...t in gas leaks and fire or explosion from the leak The hose assembly must be protected from the traffic building materials and contact with hot surfaces both during use andwhile in storage WARNING Pro...

Page 4: ...R REFROIDISSEMENT 4 COMBUSTION CHAMBER CHAMBRE DE COMBUSTION 5 BURNER BRULEUR 6 THERMOSTATS L2 BOX BOITIER THERMOSTATS L2 7 HOISTING BRACKETS TRIERS DE LEVAGE 8 SUPPORT HANDLE SUPPORT POIGNEE 9 WHEEL...

Page 5: ...INTAKE FOR PRE HEAT FILTER PRISE POUR FILTRE PR CHAUFFAGE f CABLE CLAMP FOR POWER CABLE PRESSE C BLES POUR C BLE D ALIMENTATION g TEMPERATURE CONTROLLER THERMOR GULATEUR h BURNER LIGHT VOYANT BR LEUR...

Page 6: ...f f c c d d d d d a a a e e e a GAS SELECTOR VALVE VALVE S LECTEUR GAZ b MANIFOLD PRESSURE PORT PORT PRESSION BRULEUR c MANIFOLD PRESSURE REGULATOR R GULATEUR PRESSION d MAIN GAS VALVE SOUPAPE PRINCIP...

Page 7: ...stop of the space heater In this case the heater will restart automatically when the required condition is restored The section TROUBLESHOOTING describes all possible operating faults and their possib...

Page 8: ...or ceiling must always be at least 1 metre 4 2 POWER CONNECTIONS Warning The 120V unit is fitted with a proper power cord The 220V equipment is fitted with a temporary power cable used for the final...

Page 9: ...r check that the direction of rotation of the fan matches the direction shown on the fan itself The air distribution channels can be connected by using the various accessories supplied placing the con...

Page 10: ...ter operation and not with the heater off The space heater has a gas ramp with gas filter pressure regulator safety electrovalve work electrovalve pressure stabilizer pressure valve It is good practic...

Page 11: ...y to change the kind of gas from natural gas to L P G or viceversa follow the detailed instructions indicated in section CHANGING TYPE OF GAS Only when the heater has been prearranged according to the...

Page 12: ...tests are completed the hole drilled for the probe must be sealed with a material that is resistant to high temperatures and that ensures the tube remains airtight 5 OPERATING INSTRUCTIONS 5 1 START...

Page 13: ...y set to 35 C with hysteresis of 5 C Red LED OUT 1 shows the operating state of the fan thermostat LED ON the fan is on LED OFF the fan is off Control of trip temperature of burner thermostat The temp...

Page 14: ...amaged wires or connectors if necessary 6 5 CHECKING AND TESTING THE BURNER To reach the burner Remove the burner fixing screw Remove the burner and follow the checking and cleaning instructions in th...

Page 15: ...and recalibrate the burner Incorrect setting of burner Clean and recalibrate the burner The burner goes on and off alternately and LED OUT 2 on the temperature controller is OFF when the burner goes...

Page 16: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Page 17: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Page 18: ...sea level U S A and Canada Heat input BTU h 393 052 Manifold pressure in w c 2 40 Burner head position N 4 Burner Air setting N 4 7 Fuel consumption CFH 158 40 Altitude 2 000 4 500 ft above sea level...

Page 19: ...nd Canada Heat input BTU h 593 609 Manifold pressure in w c 1 60 Burner head position N 3 Burner Air setting N 3 4 Fuel consumption CFH 239 22 Altitude 2 000 4 500 ft above sea level Canada only Heat...

Page 20: ...ut BTU h 805 499 Manifold pressure in w c 2 20 Burner head position N 5 Burner Air setting N 5 2 Fuel consumption CFH 317 16 Altitude 2 000 4 500 ft above sea level Canada only Heat input BTU h 724 95...

Page 21: ...L L 265 00 BM 21 24 NOTICE DE MONTAGE DU PIED DE LA POIGNEE FOOT HANDLE ASSEMBLY INSTRUCTION...

Page 22: ...L L 265 00 BM 22 24...

Page 23: ...L L 265 00 BM 23 24...

Page 24: ...L L 265 00 BM 24 24 BIEMMEDUE S p A Via Industria 12 12062 Cherasco CN Italy Tel 39 0172 486111 Fax 39 0172 488270 www biemmedue com bm2 biemmedue com...