Cantherm JUMBO 400 Instruction Manual Download Page 10

 

EN

 

 
L-L 265.00-BM 

10 / 24 

 

 

 

 

 

 

 

 

 

 

 

•  Secure the gas valve group to the machine using the M8 and M5 

screws. 

 

 

 

 

 

 

 

 

 

 

 

 

 

•  Remove flange D with seal E previously assembled on the burner 

cover and insert it by sliding it on the gas delivery pipe.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

•  Connect the stainless steel flexible hose to the gas valve selector 

group, taking care to properly insert the N gas seal: 

 

 

 

 

 

 

 

 

 

 

•  Locate the cable with Wieland plug running out of the gas valve 

group and insert the plug into the burner socket; 

•  Close the burner cover; 

•  The burner is not pre-adjusted by the manufacturer and must be 

set according to data reported in Table of Technical 

Characteristics of the user manual: follow the instructions in the 

manual to complete the connection of the machine to the gas 

supply system and for commissioning 

 

 

Warning 

Check all threaded connections on the gas line. 

When commissioning, check for any gas leaks or 

seepages using soap and water 

 

4.5. CONNECTION TO FUEL SUPPLY 

Warning 

The heater must be installed, set up, and used in 

compliance with all applicable regulations. 

Warning 

 

Before installing, check the gas supply conditions 

required for the type of gas chosen. 

 

 

The gas supply pipe must be properly sized, conform to the installed 

thermal power, and guarantee the necessary conditions for gas 

supply. 

 

Warning 

The gas supply pressure must be guaranteed during 

heater operation and not with the heater off. 

 

 

The space heater has a gas ramp with: gas filter, pressure regulator, 

safety electrovalve, work electrovalve, pressure stabilizer, pressure 

valve. 

It is good practice for the installer to set up the supply line as 

follows: 

 

 

 

 

 

 

 

 

 

 

 

1: filter-pressure regulator or filter 

2: antivibration joint 

3: stopcock 

4: gas ramp 

 

Parts (1), (2) and (3) are available as accessories and are not 

supplied with the heater. 

When the line has been connected: 

•  Bleed the gas supply pipe; 

•  Check that the gas pipe is sealed. 

•  Open the gas stopcock and check the seal of all connections to 

the heater. 

In case of connection of heater to natural gas, the installation shall 

conform with local codes or, in the absence of local codes, with the 

National Fuel Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas 

and Propane Installation Code, CSAB149.1. 

In case of connection to a propane supply cylinder: 

(a) the installation must conform with local codes or, in the absence 

of local codes, with the Standard for the Storage and Handling of 

Liquified Petroleum Gases, ANSI/NFPA 58 and the Natural Gas 

and Propane Installation Code, CSA B149.1. 

(b) to determine size and capacity of the cylinder(s) and for any 

specific requirements consult your LP gas supplier. In any case 

propane tank should not be lower than 100 lb (90 liters) 

(c) the cylinder supply system shall be arranged to provide for 

vapour withdrawal from the operating cylinder; 

(d) the gas shall be turned off at the propane supply cylinder when 

the heater is not in use; 

D - E 

Summary of Contents for JUMBO 400

Page 1: ...L L 265 00 BM 1 24 INSTRUCTIONS MANUAL MANUEL D INSTRUCTIONS SPACE HEATER GENERATEUR D AIR CHAUD JUMBO 400 JUMBO 600 JUMBO 800 FR EN...

Page 2: ...ING MATERIALS PAPER OR CARDBOARD AT SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PR...

Page 3: ...t in gas leaks and fire or explosion from the leak The hose assembly must be protected from the traffic building materials and contact with hot surfaces both during use andwhile in storage WARNING Pro...

Page 4: ...R REFROIDISSEMENT 4 COMBUSTION CHAMBER CHAMBRE DE COMBUSTION 5 BURNER BRULEUR 6 THERMOSTATS L2 BOX BOITIER THERMOSTATS L2 7 HOISTING BRACKETS TRIERS DE LEVAGE 8 SUPPORT HANDLE SUPPORT POIGNEE 9 WHEEL...

Page 5: ...INTAKE FOR PRE HEAT FILTER PRISE POUR FILTRE PR CHAUFFAGE f CABLE CLAMP FOR POWER CABLE PRESSE C BLES POUR C BLE D ALIMENTATION g TEMPERATURE CONTROLLER THERMOR GULATEUR h BURNER LIGHT VOYANT BR LEUR...

Page 6: ...f f c c d d d d d a a a e e e a GAS SELECTOR VALVE VALVE S LECTEUR GAZ b MANIFOLD PRESSURE PORT PORT PRESSION BRULEUR c MANIFOLD PRESSURE REGULATOR R GULATEUR PRESSION d MAIN GAS VALVE SOUPAPE PRINCIP...

Page 7: ...stop of the space heater In this case the heater will restart automatically when the required condition is restored The section TROUBLESHOOTING describes all possible operating faults and their possib...

Page 8: ...or ceiling must always be at least 1 metre 4 2 POWER CONNECTIONS Warning The 120V unit is fitted with a proper power cord The 220V equipment is fitted with a temporary power cable used for the final...

Page 9: ...r check that the direction of rotation of the fan matches the direction shown on the fan itself The air distribution channels can be connected by using the various accessories supplied placing the con...

Page 10: ...ter operation and not with the heater off The space heater has a gas ramp with gas filter pressure regulator safety electrovalve work electrovalve pressure stabilizer pressure valve It is good practic...

Page 11: ...y to change the kind of gas from natural gas to L P G or viceversa follow the detailed instructions indicated in section CHANGING TYPE OF GAS Only when the heater has been prearranged according to the...

Page 12: ...tests are completed the hole drilled for the probe must be sealed with a material that is resistant to high temperatures and that ensures the tube remains airtight 5 OPERATING INSTRUCTIONS 5 1 START...

Page 13: ...y set to 35 C with hysteresis of 5 C Red LED OUT 1 shows the operating state of the fan thermostat LED ON the fan is on LED OFF the fan is off Control of trip temperature of burner thermostat The temp...

Page 14: ...amaged wires or connectors if necessary 6 5 CHECKING AND TESTING THE BURNER To reach the burner Remove the burner fixing screw Remove the burner and follow the checking and cleaning instructions in th...

Page 15: ...and recalibrate the burner Incorrect setting of burner Clean and recalibrate the burner The burner goes on and off alternately and LED OUT 2 on the temperature controller is OFF when the burner goes...

Page 16: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Page 17: ...NTROL LAMP LAMPE TEMOIN SECURITE DE SURCHAUFFE L1 BURNER THERMOSTAT setting 90 C THERMOSTAT BRULEUR r gulation 90 C TA ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIACE RE2 DELAYED IGNITION RELAY RELAIS...

Page 18: ...sea level U S A and Canada Heat input BTU h 393 052 Manifold pressure in w c 2 40 Burner head position N 4 Burner Air setting N 4 7 Fuel consumption CFH 158 40 Altitude 2 000 4 500 ft above sea level...

Page 19: ...nd Canada Heat input BTU h 593 609 Manifold pressure in w c 1 60 Burner head position N 3 Burner Air setting N 3 4 Fuel consumption CFH 239 22 Altitude 2 000 4 500 ft above sea level Canada only Heat...

Page 20: ...ut BTU h 805 499 Manifold pressure in w c 2 20 Burner head position N 5 Burner Air setting N 5 2 Fuel consumption CFH 317 16 Altitude 2 000 4 500 ft above sea level Canada only Heat input BTU h 724 95...

Page 21: ...L L 265 00 BM 21 24 NOTICE DE MONTAGE DU PIED DE LA POIGNEE FOOT HANDLE ASSEMBLY INSTRUCTION...

Page 22: ...L L 265 00 BM 22 24...

Page 23: ...L L 265 00 BM 23 24...

Page 24: ...L L 265 00 BM 24 24 BIEMMEDUE S p A Via Industria 12 12062 Cherasco CN Italy Tel 39 0172 486111 Fax 39 0172 488270 www biemmedue com bm2 biemmedue com...

Reviews: