1

 

Service, Repairs and Modifications 

1.1

 

In General 

1.2

 

Information 

Due  to  the  special  safety  regulations  for  medical-technical  appliances  any  servicing  such  as  regular 
check-ups, repairs, modifications, calibrations etc. must only be conducted by the manufacturer or by 
persons explicitly authorized by the manufacturer.

 

1.3

 

General Maintenance and Repair Information 

Information contained in this manual is only for trained staff, who masters the required skills and safety 
measures for the repair of electronic equipment. 
The manufacturer does not assume any liability for maintenance work, repairs and modifications carried 
out by unauthorized staff. 
To be in possession of the technical documentation of the device does not provide any authorization by 
the manufacturer to  technically trained staff  to  open or repair the device. In  this manual described 
interventions are excluded from this regulation. 

1.4

 

Service Interval 

The equipment  must  be  checked  at  least  once  a  year  for  a  secure  mode  of  operation  by 
authorized service staff or by 

Cantel Medical (Italy) S.r.l.

Caution! 

Cantel Medical (Italy) S.r.l. 

does not assume liability for injuries or damages as a

result of repairs

 

conducted by non-authorized staff. 

Caution! 

While maintenance work function of 

cabinet

 is not guaranteed. For safety reasons all 

endoscopes should be stored in another cabinet during period of maintenance. 

Summary of Contents for ENDODRY

Page 1: ...one click SERVICE MANUAL...

Page 2: ...use of this publication is prohibited without the express written consent of Cantel Cantel reserves the right to make changes in the specifications shown herein without notice or obligation Contact yo...

Page 3: ...ENDODRY 13 3 6 Changing air circulation filter 14 3 7 Test function of the fan 15 3 8 Check the Door s 15 3 9 Check Bar Code Reader 16 3 10 Check Touch Display 16 4 OPERATING SOFTWARE 17 4 1 License...

Page 4: ...e work repairs and modifications carried out by unauthorized staff To be in possession of the technical documentation of the device does not provide any authorization by the manufacturer to technicall...

Page 5: ...ry Check LAN cable and connection for damage Replace them if necessary 2 2 Opening of the control system To open the control system first open the front door after that you can loosen fixing screw Air...

Page 6: ...ler Filter Flow sensor procedural method 1 switch off the cabinet 2 remove the tubes by pressing the unlocking ring towards the housing 3 loosen the screws 4 replace the filter Caution Observe the dir...

Page 7: ...ndoSTORE neo discrepancy endoSTORE one click ENDODRYTM one click Drying phase 1 0 5 bar 20 min 0 5 bar 30 min Drying phase 2 0 3 bar 0 3 bar 60 min Fan phase 180 min 180 min Storage phase 0 1 bar 0 1...

Page 8: ...s is displayed and indicates Press is displayed for ca 1 second Now key lock is activated current pressure is displayed 2 5 3 Pressure controller The pressure controller monitors the set minimum and m...

Page 9: ...Press 4th time current pressure is displayed 2 5 3 3 Completing adjustment of the pressure regulator In case that the pressure regulator needs to be exchanged or restored to factory settings the follo...

Page 10: ...times F3 adjustment of response time Press change between and Press until is displayed Confirm with and go beck to menu Press 2 times F7 adjustment of power saving mode Press change between and Press...

Page 11: ...et Tests At the yearly maintenance the following functions need to be tested 3 1 Check the Drawer Function free movement in out distortion 3 2 Check the Tube Connections tightness free movement of the...

Page 12: ...2 of 28 3 3 Check the air outlet of all nozzles not for one click models deformation mechanical influences spring function 3 4 Check the o rings of the nozzles damage pinch porosity missing o rings o...

Page 13: ...e diagnostic menu For the test an air flow tester is put on to every nozzle while air pressure pin is pushed The float of the air flow tester needs to reach the red marked range completely To check th...

Page 14: ...page 14 of 28 3 6 Changing air circulation filter Loosen screws of the cover Remove cover Change filter Change filter Fasten Cover...

Page 15: ...ke filter of the fastening pin Loosen plug Pin and fasten on new fan 3 8 Check the Door s retighten all screws door handle locking tab check the locking unit retighten screws check the hinges retighte...

Page 16: ...onnector or reader check function via Diagnostic Scanner if two sided version repeat 3 10 Check Touch Display pixel errors check touch functionality and calibrate if necessary Menu Standard Settings C...

Page 17: ...a service technician should perform 4 1 License settings Login as admin Within license settings site 2 menu it is possible to activate further addons The license key is provided by the manufacturer 4...

Page 18: ...s 1 bar Caution Change of process settings has a major influence on drying result It is highly recommended not to reduce the process settings If the customer wants a change in this setting this will h...

Page 19: ...the endoscope again Caution A change of error air pressure malfunction relative could lead to displaying a successfully completed process even if endoscopes have had insufficient air pressure 4 4 Ser...

Page 20: ...the installer file Endodry Endostore_setup3 X XXXX exe to one of the available USB ports on the cabinet 2 On the USB memory stick double click on the installer file Endodry Endostore_setup3 X XXXX exe...

Page 21: ...page 21 of 28 4 Check the Generate unique computer name box Important This checkbox is deactivated by default On the first installation it must be set manually to be active...

Page 22: ...ch need to be installed and press the Next button Each cabinet version can be installed as a Master or Slave device Th NDODRY e following cabinet versions including legacy cabinets are available E END...

Page 23: ...page 23 of 28 6 Press the Install button to install the Endodry application...

Page 24: ...page 24 of 28 7 Press the Finish button once the application indicates the installation is complete 8 Installation complete...

Page 25: ...33 l min 5 Bar 7 SCFM 1 2 CFM 72 5 PSI 6 1 4 according to ISO 8573 1 2010 1 4 1 Dimensions cm Weight kg Operating conditions Storing conditions Maximum relative humidity 80 for temperatures up to 31 C...

Page 26: ...page 26 of 28 6 Colour touch screen I IP 20 Display Electrical protection class IP code...

Page 27: ...ly note the different value cabinet tests o function of the drawers drawer rails o tube connections o functionality condition of inlet air pins o o rings of the nozzles if applicable replace o air out...

Page 28: ...page 28 of 28 7 Technical Service Information Date Inspection Signature...

Reviews: