HOOKUP CONNECTOR BLOCK LABEL

The Hookup Connector Block Label contains useful information for quick reference.

Handle Locking Instructions

 - insert block onto basin channel manifold and 

move handle to the left to lock. Move to the right to unlock.

Lot Number

 - identifies date of manufacture.

Hookup Part Number

 - identifies hookup.

Hookup Barcode

 - barcode of part number.

Port Name

 - identifier of port location in ADVANTAGE system. Error logs identify 

issues using these names. Also identifier of Connector Assembly replacements for 

older model hookups.

Port ID Number

 - identifier for Connector Assembly replacements. Not found on 

older model hookups. 

Alternative Channel Connector Names

 - connector names vary depending 

on specific endoscope channel configuration.

WARNINGS & CAUTIONS

This hookup is intended for connection only with the specific endoscope models identified in the appropriate MEDIVATORS online hookup guide. Use of this 
hookup with endoscopes other than those specified by the hookup application guide may result in inadequate HLD.
Users operating MEDIVATORS AERs and hookups must be trained and competent in the understanding of endoscope channel systems.
Prior to reprocessing, users must verify that the hookup used contains connections for all appropriate channels that require a separate reprocessing connection 
according to the hookup instructions
All connectors and adapters must remain firmly attached and unrestricted for the entire disinfection cycle to ensure adequate HLD. Users must inspect the 
endoscope and hookup combination to verify proper connection and flow.
Modifications or repairs to hookups which do not correspond to the manufacturer’s specifications may result in inadequate HLD and/or damage to endoscopes.
Failure to properly clean and prepare endoscope for immersion prior to hookup connection may result in inadequate HLD and/or damage to the endoscope.
Endoscopes must be inspected for damage and verified to be in proper working order prior to hookup connection.  Connection of hookups to damaged 
endoscopes or endoscopes with obstructed/restricted channels could result in inadequate HLD.
Manual leak testing must be carried out in accordance with manufacturer’s recommendations prior to reprocessing.
Install all necessary waterproof caps, plugs and cleaning adapters prior to immersion.
Do NOT autoclave MEDIVATORS hookups.
MEDIVATORS makes no claim on high-level disinfection efficacy when these reprocessing instructions are not followed, or when this hookup kit is applied to 
endoscopes other than those specified in the online interactive hookup guide.
Avoid biological contamination. Always wear personal protective equipment when handling endoscopes.

LOT XXXXXX ID: XXXX

P/N: X-X-XXX

Medivators Inc.

14605 28th Ave N.

Minneapolis, MN 55447

USA
Medivators BV

Sourethweg 11

6422PC Heerlen

The Netherlands

 

 

Hookup Part Number

Hookup 

Barcode

Port ID 

Number

Port Name

Alternative 

Channel 

Connector 

Names

Handle Locking 

Instructions

Lot Number

Medivators BV
Sourethweg 11
6422PC Heerlen
The Netherlands
Tel:  +31.45.5.471.471

Cantel Medical Asia/Pacific Pte. Ltd.
1A International Business Park
#05-01 Singapore 609933
Tel:  +65.6227.9698

www.medivators.com