background image

arm holder

step3

step1

Do s

ilicon

 work at the 

front frame caps and the 

gutter frame caps as 

shown in the detailed 

figure.

step6

step4

step5

Fix the side frame fixing 

bracket (under) to the 

post with hexagon bolts 

M10○25.

Put the side frame on the side 

frame fixing bracket(under), and 

fix it to the post with hexagon 

bolts M10○25.

Fix the arm to the arm holder 

with hexagon bolts M10○95.

Fix the bolt M8○20 of  

the side frame 

completely.

Be sure to insert the 

two washers to the bolt 

M10○95.

The side frame fixing bracket

(under)has right-left. Install it as 

below figure.

Detailed figure of  the s

ilicon

 part.

indicates the s

ilicon

 part.

hexagon bolt
M10×25

(parts box)

hexagon bolt
M10×95-30

(parts box)

washer 10

washer 10

spring washer 10

spring washer 10

cap nut M10

≧parts box∞

≧parts box∞

≧parts box∞

≧parts box∞

≧parts box∞

≧parts box∞

≧parts box∞

≧parts box∞

washer 10

≧parts box∞

side frame

post

side 

frame

B view

B view

arm

side frame

fixing bracket≧upper∞

side frame

fixing bracket≧under∞

The higher side is front frame side.

front frame
side

gutter
side

front frame cap≧Single∞

gutter cap≧Single∞

gutter cap≧Wide∞

front frame cap≧Wide∞

Ins tallation of Gutter・Front Frame

side frame

fixing bracket≧under∞

Summary of Contents for Assembly Instructions

Page 1: ...allation Manual Thank you very much for choosing our company s Cantaport products Please be sure to thoroughly read these instructions for assembling the Cantaport product in conjunction with the engi...

Page 2: ...below to prevent aluminum materials corrode sea sand cement enhancer water reducing cryopro tectant 1 Do not use sea sand for the foundation since it contains salt and may cause corrosion Do not use a...

Page 3: ...imension Position of Posts and Base Dimension Dimension Position of Post Single D24 D27 D30 Wide D48 D54 D60 Length Dimension W Height Dimension H and Post Standard Position post could be changed as t...

Page 4: ...elding wire net are arranged in concrete floor Dimension of projection which prevents floating at 4 rounds is more than 50mm 50mm Distance A from outside edge of base to around concrete floor is more...

Page 5: ...shaped gutter 5 parts U shaped gutter 3 parts U shaped gutter 5 parts U shaped gutter 3 parts type Single Wide body size Depth D Length W standard post long post post main frame component parts type...

Page 6: ...ts post cap post set R single post front frame side post gutter side post connecting parts post set L single post set L single hexagon bolt with washer spring washer M8 25 post front frame side post g...

Page 7: ...be sure to return to the owner notice small truss screw 5 10 10 post ornament ornament bracket flat head screw 4 12 8 flat head screw 4 12 8 drilling screw 4 10 8 arm arm set wide arm hexagon nut M8...

Page 8: ...main frame Right Left each 2 pcs Right Left each 2 pcs roof rafter set single gutter front frame set single gutter front frame set wide main frame set anchor rod arm hanging bracket arm holder back p...

Page 9: ...frame cap single gutter cap single gutter cap wide arm cap side frame fixing bracket cap post ornament cap front frame cap wide content name quantity Parts ID shape content name quantity Parts ID shap...

Page 10: ...polycarbonate mat panel When mark is CP it is the heat protection polycarbonate panel When mark is CF it is the heat protection FRP panel drilling screw elbow drain elbow saddle glue caution label sno...

Page 11: ...ont frame Installation of the main frame Installation of the roof rafter Fixing the side frame Installation of the roof panels Installation of the roof retainer Attaching the round gutter parts post m...

Page 12: ...of the connecting parts is upper side U shaped gutter U shaped up Fix the post fixing bracket with small truss screw 5 10 10 note note Fix the all hexagon bolts and fasten completely because this par...

Page 13: ...post ornament cover Install the opposite side in the same way step2 Insert the post caps on the top and screw it with the flat head screw 4 12 8 drilling screw 4 10 8 post ornament set post set flat h...

Page 14: ...the arm side The figure indicates right side step4 Insert the anchor rod into the post hole anchor step5 support stand plumb bob Insert post into the base hole and fix with support stand not to fall...

Page 15: ...right left Install it as below figure The higher side is gutter side Fix the arm holder and the side frame fixing brackets as below front frame side front frame side gutter side gutter side note hexag...

Page 16: ...side frame fixing bracket under has right left Install it as below figure Detailed figure of the silicon part indicates the silicon part hexagon bolt M10 25 parts box hexagon bolt M10 95 30 parts box...

Page 17: ...side gutter side parts box small truss screw 5 10 10 parts box small truss screw 5 10 10 side frame side frame front frame side frame After connecting each frames with small truss screws as figure In...

Page 18: ...Single Wide Single Wide Installation for Single is 3 screws For Wide is 4 screws 2 screws on top face and other 2 screws on down face step1 step2 Attach the roof panel cushions on the top side of all...

Page 19: ...gonal dimension of roof Put the roof rafter into the front frame and screw it with driling screws 4 10 8 B part B part detail U shaped gutter U shaped gutter At A part screw it to guide hole At B part...

Page 20: ...will run idle Holder part of the side frame after making 5 hole on the top face of the fin make 3 hole on the second fin Put the caps onto the side frame fixing bracket under After making 3 hole to th...

Page 21: ...se the panel color may change by sunlight The panel width has two size when D24 30 48 54 60 the wider panel width 703mm put at both ends and the smaller one width 575mm put at midspan In only case of...

Page 22: ...truss screw 4 10 7 parts set front frame cap silicon If the screws of retainer middle part tighten too much the screw will run idle tightening torque less than15kgf cm If the screw head leans when in...

Page 23: ...of rain gutter Installation of gutter hole cap Detailed figure of the silicon part Be sure to do sealing work around screws in order to prevent danger when cleaning as well as for water proof silicon...

Page 24: ...2018 RUSSELL WHITE 116216 0 RUW ISSUE FOR APPROVAL 11 10 18 CANTAPORT GROUND FLOOR BUILDING 2 630 MITCHAM ROAD MITCHAM VIC 3132 TEL 03 8872 6999 FAX 03 9873 2777 EMAIL melbourne structerre com au CAN...

Page 25: ...GS TO SUIT EXPOSURE CLASSIFICATION f ALL WORK GENERALLY TO BUILDING CODE OF AUSTRALIA AND ALL RELEVANT BUILDING STANDARDS AND CODES g ALL SCREWS SIZES AS PER DETAILS COATING TO SUIT EXPOSURE CLASSIFIC...

Page 26: ...ANTAPORT ARCHITECTURAL DRAWINGS FOR PURLIN TYPE DE5934 T5 56 5 22 1 5 T 1 5mm min 2 REFER TO CANTAPORT ARCHITECTURAL DRAWINGS FOR ARM TYPE DE5913 T5 60 T 3 5mm min REFER TO CANTAPORT ARCHITECTURAL DRA...

Page 27: ...S 1 PINS MUST HIT REFUSAL ROCK OR EXTEND MIN 1200mm INTO NATURAL OCCURRING CLAY 2 MIN PIN LENGTH OF 2000mm 12x PINS REQUIRED MIN 3 HOLES MAY NEED TO BE PREDRILLED WHEN ENCOUNTERING ROCK REFER TO SUREF...