SmartLock

®

 Pro 

Page 14 of 29 

 

Installation Manual 

April 2009 • Rev. 1.7 

+VDC

GND

BEEPER

GREEN LED

D1
D0

+VDC

GND

BEEPER

GREEN LED

D1
D0

GND

+12 VDC

EXIT READER

*OPTIONAL

**CONTROLS ENTRY READER LOCK

ENTRY READER

SET READER 

VOLTAGE

1

 2

 3

 4

 5

 6

 7

 8

O

N

O

N

8

1

+

5

V

+

1

2

V

N/O

N/C

O

F

F

N/C

N/C

N/O

N/O

WIEGAND
DATA LED

Reader Wiring 

 

WIEGAND READER 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

IMPORTANT: 

Before applying power to the controller, verify that the 

reader voltage jumper is set correctly for the reader being connected. 
Connecting a 5 V reader to a 12 V power supply will damage the reader. 

 
NOTE:

 The SmartLock

®

 controller supports Cansec’s 37-bit format as well as 

standard 26-bit format. 

CABLE: 22 AWG, 6 CONDUCTORS, 
NON-TWISTED PAIR, OVERALL 
SHIELDED, MAX. DISTANCE IS 
500ft (152 m). 

 

Summary of Contents for SmartLock Pro

Page 1: ...SmartLock Pro INSTALLATION MANUAL April 2009...

Page 2: ...Dial Up 12 Remote End Dial Up 12 Programming module Stand Alone 13 READER WIRING 14 Wiegand Reader 14 iButton Reader 15 LOCK OUTPUT RELAY WIRING 16 DC Electric Strikes 16 DC MagLocks 17 AC MagLocks a...

Page 3: ...The SmartLock control panel stores all cardholder data in non volatile memory to ensure continued operation and security in the event that communications are lost to the host PC Up to two control pane...

Page 4: ...MARR connector wire nut marrette thimble connector cone connector Splice the thicker cable to a cable that is the appropriate thickness and then run the thinner cable to the terminal strip on the con...

Page 5: ...lease may be required Installers should contact the local authority having jurisdiction to verify the specific requirements Also a building permit may be required in some jurisdictions for the install...

Page 6: ...ll shield 152 m 500 ft max total length iButton Readers 6 conductors 22 AWG shielded or unshielded 15 m 50 ft max total length Dimensions Weight Controller Board 84 mm l x 65 mm w 3 5 16 l x 2 9 16 w...

Page 7: ...CED DHO DOOR OPER Important Notes 1 Each controller must have a unique address Refer to the Controller Address Table 2 Exit reader must be Wiegand only Native iButton reader not supported for exit 3 B...

Page 8: ...ly flickers when valid Wiegand data is received from the reader If Wiegand data is not valid or not supported this LED will stay OFF until the next valid card is read 3 The communication LED will flic...

Page 9: ...Wiring Up to 30 SmartLock access control panels may be connected on an RS 485 bus An additional 30 control panels may be connected via a Cansec communications device NOTE For CLA50 communications dev...

Page 10: ...F N C N C N O N O Each Smartlock controller must have a unique address For communication wiring use 22 AWG twisted pair stranded shielded cable 2000 ft MAX total length 609 m Use the CLAUSB factory de...

Page 11: ...n wiring use 22 AWG twisted pair stranded shielded cable 2000ft MAX total length 609 m Canlan needs to be configured for RS 485 communications Refer to the Canlan Installation and Configuration guide...

Page 12: ...D RS 485 B A GND GND 12 VDC ON 8 1 5V 12V N O N C OFF N C N C N O N O ADDRESS 1 SHOWN Dipswitch 1 is OFF A B GND SHIELD 12 VDC PLUG IN TRANSFORMER 2 1 mm PLUG CENTRE POSITIVE SUPPLIED CUSTOM MODEM CAB...

Page 13: ...Button reader is being used wire it to the same reader port in parallel with the programming module The programming module comes in a plastic box Drill the required holes for mounting and feed the cab...

Page 14: ...C OFF N C N C N O N O WIEGAND DATA LED Reader Wiring WIEGAND READER IMPORTANT Before applying power to the controller verify that the reader voltage jumper is set correctly for the reader being conne...

Page 15: ...nual April 2009 Rev 1 7 iBUTTON READER NOTE Exit reader not supported with SmartLock iButton readers NOTE If using the SmartLock Connect Programming Module with iButton readers connect the programming...

Page 16: ...Page 16 of 29 Installation Manual April 2009 Rev 1 7 Lock Output Relay Wiring DC ELECTRIC STRIKES NOTE Use 1N400x series diode as shown to prevent back EMF from damaging the controller Option 1 250mA...

Page 17: ...9 Rev 1 7 DC MAGLOCKS NOTE Use 1N400x series diode as shown to prevent back EMF from damaging the controller if the maglock is not equipped with sufficient spike and surge protection Check the maglock...

Page 18: ...SmartLock Pro Page 18 of 29 Installation Manual April 2009 Rev 1 7 AC MAGLOCKS AND AC ELECTRIC STRIKES...

Page 19: ...act input Otherwise the door will be in alarm condition NOTE Exit Button requires momentary closure to activate relay Door Contact is used for forced entry and door held open annunciation and also dea...

Page 20: ...entary closure to activate relay 1 2 3 4 5 6 7 8 ON OFF ON 8 1 5V 12V N O N C N O N O N C N C SET RELAY CONTACTS N O N C LOCK DOOR OPER FORCED DHO RELAY LEDS TURN ON ACTIVATION RED DOOR OPERATOR OUTPU...

Page 21: ...used to erase the controller s memory and run diagnostics to enable or bypass the door contact input and to set the controller address from 0 to 60 0 for stand alone only LOCATION 1 2 3 4 5 6 7 8 ON W...

Page 22: ...t power from the board momentarily then re connect power 4 The controller s memory will be erased All three relays will cycle ON OFF once the memory has been cleared Relay outputs can be verified duri...

Page 23: ...ON OFF IF YOU ARE CONNECTING A DOOR CONTACT SET DIP SWITCH 8 TO OFF LEFT IF YOU ARE CONNECTING A DOOR CONTACT SET DIP SWITCH 8 ON RIGHT NOT Door Contact Connected Set switch 8 OFF LEFT on diagram Door...

Page 24: ...sing the Stand Alone Programming Module set the controller switch settings as follows 1 Locate DIP switch position 8 using the diagram above 2 Set switch positions 1 through 6 to the ON position addre...

Page 25: ...establish communications Switch setting changes do not take effect until the power is disconnected then reconnected ADDRESS SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 STAND ALONE 0 ON ON ON ON ON ON 1 OFF ON ON O...

Page 26: ...F OFF OFF ON OFF ON 24 ON ON ON OFF OFF ON 25 OFF ON ON OFF OFF ON 26 ON OFF ON OFF OFF ON 27 OFF OFF ON OFF OFF ON 28 ON ON OFF OFF OFF ON 29 OFF ON OFF OFF OFF ON 30 ON OFF OFF OFF OFF ON 31 OFF OFF...

Page 27: ...ON ON ON OFF OFF 49 OFF ON ON ON OFF OFF 50 ON OFF ON ON OFF OFF 51 OFF OFF ON ON OFF OFF 52 ON ON OFF ON OFF OFF 53 OFF ON OFF ON OFF OFF 54 ON OFF OFF ON OFF OFF 55 OFF OFF OFF ON OFF OFF 56 ON ON O...

Page 28: ...ng use 22 AWG twisted pair stranded shielded cable 2000 ft MAX total length 609 m open the CLA50 and change the jumper settings or DIP switch settings DO NOT NOTES ADDRESS 1 SHOWN Dipswitch 1 is OFF G...

Page 29: ...SmartLock Pro Page 29 of 29 Installation Manual April 2009 Rev 1 7 SmartLock is a registered trademark of Cansec Systems Ltd iButton is a registered trademark of Maxim Integrated Products Inc...