background image

 

 

22 

Restore Tool Operating Procedure

 

  The following message is displayed when the [Click] button was clicked to close Restore 

Tool with the log file unsaved, after the log file failed to be saved. 

 

 

 

 

 

 

[Restore Tool is about to be closed.] 

 

 

  If the log file already exists, new logs will be added to the file. If you specify the existing log file to 

save a log file manually after the log file failes to be saved, the file will be overwritten 

  The date format is YYYY/MM/DD. 

 

 

3.5.  Version Information of Restore Tool 

 

  Click the icon on the upper left corner of the Restore Tool dialog to display the menu. 

Choose [About VB-C300 Restore Tool Version] from the menu, and the information dialog 

box appears, which shows the version of Restore Tool. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VB-C300

Page 1: ...te 1 All rights reserved 2 The contents of this manual are subject to change without notice 3 Notwithstanding above 2 items Canon accepts no responsibility for any effects resulting from use of this m...

Page 2: ...6 2 5 Read Camera Information from Camera Specification File 9 2 6 Deletion of Camera Information 13 2 7 Log List and Log File Saving 14 2 8 Backup File 16 2 9 Version Information of Backup Tool 16 3...

Page 3: ...States and other countries Windows is legally recognized as Microsoft Windows Operating System Other brand or product names in this Manual may be trademarks or registered trademarks of their respectiv...

Page 4: ...name as the log file the log information will be added to the backup file So don t use the same name for backup files as the log file The log file name is originally set to VBC300BK log Restore Tool...

Page 5: ...ways of selecting cameras to be backed up Enter necessary information for each camera one by one in Camera Information Entry Dialog see page 6 Read Camera Information from Camera Specification File se...

Page 6: ...button to select and add a file from the file save dialog Overwrite Check Checked The backup file will be overwritten if the file already exists Not checked The backup file won t be overwritten if the...

Page 7: ...ht side in the center of the dialog box Ex 5 30 5 camera information is already registered max 30 Execution Click Start to execute the backup process Repeat the process from to to backup multiple came...

Page 8: ...dialog box For more information about the logs please refer to section 2 7 page 14 Note If a backup file is saved as the same name as the log file the log information will be added to the backup file...

Page 9: ...fication file A camera specification file is a CSV format file including a list of camera information of which you want to backup the setting values Camera specification files need to be created in ad...

Page 10: ...save flag for a backup file 0 Not Overwrite 1 Overwrite Default Not Overwrite Contents of a camera specification file Examples of a camera specification file Information for one camera should be liste...

Page 11: ...wever if the administrator password has not been changed from the factory default value VB C300 the password can be omitted in the camera specification file If there are any unnecessary blank lines in...

Page 12: ...Procedure Execution Click Start to execute the backup process Upon completion of the backup process the results are displayed in the log list dialog box For more information about the logs please refe...

Page 13: ...Delete Camera Information button to delete added camera information from a camera information list Select camera information from the list and click the Delete Camera Information button The Delete Ca...

Page 14: ...l exe file VBC300BK exe is located The log file is automatically saved as VBC300BK log If the log file fails to be saved the Save button will appear in the log list dialog which enables you to save th...

Page 15: ...t the backup process before closing the log list dialog The close button was pressed to close Backup Tool If the log file already exists new logs will be added to the file If you specify the existing...

Page 16: ...r change the contents when opening a backup file using editor The date format is YYYY MM DD 2 9 Version Information of Backup Tool Click the icon on the upper left corner of the Backup Tool dialog to...

Page 17: ...Restore Process Flow Following is the restore process flow 3 2 Boot Up Double Click on exe file VBC300RS exe to boot Restore Tool Camera Information Entry Dialog Booting Restore Tool Selecting camera...

Page 18: ...Name Enter the name of a backup file to be restored in the absolute path Click the Browse button to select and add a backup file from the dialog Note Setting values cannot be restored to multiple came...

Page 19: ...ot to be restored The following message is displayed when clicking Start after checking the box Note When the administrator password authorized user passwords and the user list are restored those sett...

Page 20: ...20 Restore Tool Operating Procedure Execution Click the Start button to execute the restore process The camera will be rebooted automatically if the restore process completed successfully...

Page 21: ...ly saved in a folder where Restore Tool exe file VBC300RS exe file is located The log file is saved as VBC300RS log If the log file fails to be saved the Save button will appear in the Restore Tool di...

Page 22: ...ew logs will be added to the file If you specify the existing log file to save a log file manually after the log file failes to be saved the file will be overwritten The date format is YYYY MM DD 3 5...

Page 23: ...on 001 Processing started The backup process started 002 Processing completed The backup process completed 003 Processing cancelled The backup process was canceled using the Cancel button 004 Processi...

Page 24: ...version is unmatched Configuration of the file has been changed because of version upgrade etc 212 The specified backup file cannot be used with this restore tool because of the newer version Version...

Page 25: ...a information entry dialog was clicked both with the log file unsaved and with the log dialog unclosed after the log file failed to be saved The log file is not saved yet Are you sure you want to clos...

Page 26: ...tomer Information Centre toll free at 1 800 OK CANON 652 2666 Canada only MEXICO CANON MEXICANA S DE R L DE C V Boulevard Manuel Avila Camacho No 138 PB Pisos 15 16 y 17 Col Lomas de Chapultepec CP 11...

Reviews: