background image

Canon
SX80 
Summary of Remote Control Commands (User Commands)

1. Connection

Use the cable to connect the projector (service port) to the computer (RS-232C serial port). 
The computer and projector should be connected in a direct, 1:1 connection. 

If the number of pins on the connectors or the formats do not match, an adapter is required. 

Computer: Directly connected to the projector (1:1)

Three-line connection: SD, RD, and SG

9-pin RS-232C cable (cross) 

Send Data SD

SD Send Data

Receive Data RD

RD Receive Data

Signal Ground SG

SG Signal Ground

* In the SX80, only the three signal lines of SD, RD, SG are used

2. Communication Format

Specifications

RS-232-C start-stop synchronization, semi-duplex communication

19200 bps 

8 bits 

2 bits 

None

None

Specifications

Variable-length (up to 256 bytes including delimiter) 

CR, LF, CR+LF, or null (00h)

In messages, CR is indicated as <CR>, LF as <LF>, CR+LF as <CR>+<LF>, and null as <00>. 

ASCII code (typical characters: 20h to 7Fh) 

Case-insensitive. 

<CR> is 0Dh, <LF> is 0Ah, <CR>+<LF> is 0Dh0Ah, and <00> is 00h. 

No protocol

None

None

Not supported

Between characters

: 5 seconds

(However, timeout between CR and LF is 10 ms)

<1 byte>

<1 byte>

Within 5 seconds

Period between command and response: 10 seconds

Command

Within 10 seconds

Response

The next command must not be sent without waiting for the response

If the next command is sent, an error will occur

Flow Control

Error Control

Break Signal

Timeout

Character Length

Stop Bit

Computer

Projector

Item

Number of Bytes

Delimiters

Message Codes

Protocol

Parity

Flow Control

Item

Specifications

Connection Method

Signal Lines to Connec

Cable to Connect

Item

Communication Method

Transmission Speed

Computer

Projector

Dedicated cable

COM

Port

Service

Port

Canon

Summary of Contents for REALiS SX80 Mark II D

Page 1: ...able length up to 256 bytes including delimiter CR LF CR LF or null 00h In messages CR is indicated as CR LF as LF CR LF as CR LF and null as 00 ASCII code typical characters 20h to 7Fh Case insensiti...

Page 2: ...n Turn off the device check the communication cable and resend the command END Command Transmission Response received YES NO Response Reception Has 10 seconds elapsed NO YES First failure YES NO Confi...

Page 3: ...52h 47h 42h 0Dh DigitalVideo INPUT HDMI CR 49h 4Eh 50h 55h 54h 3Dh 48h 44h 4Dh 49h 0Dh AnalogPC1 INPUT A RGB1 CR 49h 4Eh 50h 55h 54h 3Dh 41h 2Dh 52h 47h 42h 31h 0Dh AnalogPC2 INPUT A RGB2 CR 49h 4Eh...

Page 4: ...49h 4Dh 41h 47h 45h 3Dh 50h 52h 45h 53h 45h 4Eh 54h 41h 54h 49h 4Fh 4Eh 0Dh SRGB g IMAGE SRGB CR 67h 3Ah 49h 4Dh 41h 47h 45h 3Dh 53h 52h 47h 42h 0Dh MOVIE g IMAGE MOVIE CR 67h 3Ah 49h 4Dh 41h 47h 45h...

Page 5: ...Contrast Commands Commands for setting the contrast or for acquiring the contrast setting value PC PRJ Setting value CONT number CR 43h 4Fh 4Eh 54h 3Dh character code 0Dh GET CONT CR 47h 45h 54h 20h 4...

Page 6: ...7h 3Ah 41h 53h 50h 45h 43h 54h 3Dh 31h 36h 3Ah 39h 0Dh Zoom g ASPECT ZOOM CR 67h 3Ah 41h 53h 50h 45h 43h 54h 3Dh 5Ah 4Fh 4Fh 4Dh 0Dh Actual g ASPECT TRUE CR 67h 3Ah 41h 53h 50h 45h 43h 54h 3Dh 54h 52h...

Page 7: ...20h 42h 4Ch 41h 4Eh 4Bh 0Dh 12 2 Execute Blank Responses Responses to commands for executing the Blank function or for acquiring the Blank function value PRJ PC Success i OK CR 69h 3Ah 4Fh 4Bh 0Dh Fa...

Page 8: ...esend the command after you finish operations in the current menu mode has been canceled e 1009 NOW_FREEZE Cannot execute command Freeze in progress Resend the command after freeze operation has been...

Page 9: ...returned However errors of the same number are ranked with the same priority i INPUT_NOT_FOUND Input not switched No input signal when AUTOSETEXE INPUT No particular measures regarding notification o...

Reviews: