10
5. Adjustment Procedure
5.1 IS 1 Adjustment
5.1.1 Auto Adjustment
■
Tools Used
1
Click the “IS 1” button.
2
1. When the message on the right appears, enter
the value written on the Optical Unit Flex in the
Focus Sink text box, and then click the “Update”
button.
2. After the update is complete, proceed to step 3.
3
1. Set the camera so that it faces the lens of the
collimator.
* The lens attached to the camera moves during
the adjustment, so be sure to leave about a
distance of 1 cm between the camera lens and
the collimator lens.
2. Adjust the height of the camera and the
collimator so that the LED point light source is
at the center of the camera's LCD.
3. Click the “ADJUST” button.
•
Personal Computer
•
SERVICE MANUAL
•
ADJUSTMENT SOFTWARE
•
Compact Power Adapter CA-PS700
•
AC Cable
•
DC Coupler DR-50
•
INTERFACE CABLE IFC-400PCU
•
COLLIMATER IS AUTO
ADJUSTMENT
Collimeter IS
Auto Adjustment
Power
Source
Stand
Personal
Computer
CAMERA
BODY