2-26) Remove the 1 screw [1] to remove the Fixing bracket [2]. Then move the Tray guide unit [3]in the direction of arrow to
remove it.
CAUTION:
When removing the Fixing bracket, pay attention not to drop the torsion spring [4] inside the machine.
2-27) Remove the Tension spring [1] hooked on the Shutter with a pair of needle nose pliers or the like (by one side only).
102