4
4
4-41
4-41
Disassembly/Assembly > Controller System > Removing the Fixing Delivery/Paper Width Sensor PCB > Procedure
Disassembly/Assembly > Controller System > Removing the Fixing Delivery/Paper Width Sensor PCB > Procedure
5) Free the harness [1] from the Harness Guide [A], and remove the Fixing Delivery/Paper
Width Sensor PCB [2].
• 1 Connector [3]
• 2 Claws [4]
[A]
[1]
x2
[3] [4]
[4]
[2]
NOTE:
The picture below shows how to route the harness.
F-4-100
F-4-99
CAUTION:
When installing the terminal [1], be sure that the Contact Spring [2] is in contact with it.
[2]
[1]
F-4-101