82
Item
Operation
Commands
Values
Notes
6-7-2
v.refresh
?
<string>
Note2
6-8
lamp1.hours
?
<string>
6-9
lamp2.hours
?
<string>
6-10
proj.runtime
?
<string>
6-11
fact.reset
(execute)
A. Others
Item
Operation
Commands
Values
Notes
A-1
power.on
(execute)
A-2
power.off
(execute)
A-3
status
?
0 = standby
1 = warm up
2 = imaging
3 = cooling
4 = reset
A-4
errcode
?
Ref to Appendix A
A-5
psoc.ver
?
Ger firmware version of PSOC
A-6
adc.rd
?
Get ADC calibration data
A-7
f336.ver
?
Ger firmware version of F336
A-8
blst.ver
?
Ger HW & FW version of Ballast
A-9
dlpsoc
(execute)
Download PSOC latest SW
A-10
color.native
=?
0: Color setting normal for picture
quality (default)
1: Color setting native for optical
data measurement
A-11
edid.rd.vga
?
Read VGA edid
A-12
edid.rd.hdmi
?
Read HDMI edid
A-13
edid.rd.dvi
?
Read DVI edid
A-14
edid.rd.dp
?
Read DVI edid
A-15
lamp1.reset
(execute)
Reset the lamp1 hours
A-16
lamp2.reset
(execute)
Reset the lamp2 hours
B. “ky” commands
The syntax of “ky” commands is as following:
ky[SP]<Operation>[CR]
The “ky” commands are unusable when in Network setting of Standby Mode.
Item
Operation
Actions
B-1
power.on
Power on immediately
B-2
power.off
Power off immediately
B-3
menu
Act the same as IR remote control MENU key
B-4
exit
Act the same as IR remote control EXIT key
B-5
enter
Act the same as IR remote control ENTER key
B-6
up
Act the same as IR remote control UP key
B-7
down
Act the same as IR remote control DOWN key
B-8
left
Act the same as IR remote control LEFT key
B-9
right
Act the same as IR remote control RIGHT key
B-10
nop
No operation (just to know projector is alive)