A1
SCH_MW6P
MW6P-01
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
E
F
G
H
I
J
K
A
B
C
D
E
F
G
H
I
J
K
L
INTAKE FAN
EXHAUST FAN
INTAKE FAN
INTAKE FAN
(NEUT)
(LIVE)
1AV4T30B05900
150W
(SET TO OPEN AT 100+/-5˚C)
AC100-120V
AC200-240V
F.G.
INTAKE FAN
INTAKE FAN
INTAKE FAN
1
4
VCC
VOUT
GND
1
3
K48J
FN906
FN903
FN902
K66E
K66D
K66C
FN905
K66B
K66A
SP901
K25V
K22V
K56P
K26P
K4M
K8M
K8L
K4L
K50B
K10B
K10A
R
LCD
PANEL
G
LCD
PANEL
B
LCD
PANEL
K25R
K25G
K25B
K50A
FN901
K5P
INLET
CB1
SW902
METAL HALIDE LAMP
CN101
K8D
K902S
K901S
SW904
K903S
K904S
CN102
CN103
K56M
K48K
K56N
CN202
CN201
K66F
K66G
FN907
FN904
CB2
K0W
K72S
K72Y
K28D3
K28D2
K28D1
R2801
R2802
C2801
C2802
K28D
A2801
D2802
D2801
X
M10B20101
M10B12104
M10B12104
J10EG
030G
J10EG
030G
J10EG
030G
M10B20101
J10EG
030G
J10EG
030G
A10B23000
3
1
1
3
3
1
1
3
3
1
30
1
1
30
30
1
1
2
20
19
19
20
2
1
1
2
20
19
19
20
2
1
1
2
50
49
49
50
2
1
1
2
50
49
50
49
2
1
2
1
39
40
40
39
1
2
2
1
39
40
40
39
2
1
J10DT200G
J11LP200G
J11LP200G
J10DT200G
J10DT500G
J11LP500G
J11LP500G
J10DT500G
J10ML400G
J11MD400G
J11MD400G
5
1
3
1
J11EA300G
J11EA300G
J11EA300G
J10ML400G
1
4
M10B21700
J10EP
030G
1
3
X
X
S10B3590N
X
J10EG
040G
J11B
2450N
J11B
2450N
S10B3370N
J11B
2450N
J11B
2450N
X
X
X
X
X
X
X
J10EG
030G
J10ES
030G
M10B08202
M10B12104
3
1
3
1
X
J10EG
040G
J10EZ090G
J10EZ090G
1
9
9
1
NT1
NT1
NT1
1/16GJ
47C
1/16GJ100C
10KZ1U
GQFZ
KK470
GQBY
J10EG040G
U22B0010G
X
X
5V
AL
ASSY,PWB,AV MW6A
1AA0B10C346A0
ASSY,PWB,SUB MW6A
1AA0B10C343AB
INTER LOCK
SW
LAMP BALLAST
A901
1AV4U20B41400
ASSY,PWB,MAIN MW6P
1AA0B10C343DA
AC CORD
ASSY,PWB,R/C MW6A
1AA0B10C343AC
TERMOSTAT
SW
REMOTE
CONTROL
PRE-AMP
POWER UNIT
A601
1AV4U20B41800
CAUTION
Fuse of the specified parts number must be used.
Unauthorized substitutions may result in fire or accident.
Components indicated by a mark in this schematic diagram designate
components in which safety can be of special significance. It is, therefore,
particularly recommended that the replacement of these parts must be
made by exactly the same parts.
This projector is isolated from AC line by using the internal converter
transformer.
Please pay attention to the following notes in servicing.
1 Do not touch the part on hot side (primary circuit) or both parts on
hot and cold sides (secondary circuit) at the same time.
2 Do not shorten the circuit between hot and cold sides.
3 The grounding lead must be connected to the ground of the same
circuit when measuring of voltages and waveforms.
CAUTION
LP901
P-1
■
Schematic Diagrams
Summary of Contents for LV-X1J
Page 8: ...Part 1 General Information ...
Page 23: ...Part 2 Repair Information ...
Page 35: ......
Page 36: ...Part 3 Adjustment ...
Page 47: ...Part 4 Parts Catalog ...
Page 48: ......
Page 56: ...U 1 U 2 Z V 1 Page 4 CANON LV X1J LV X1U LV X1E REF No D78 5241 D78 5242 D78 5243 Y X ...
Page 59: ......
Page 60: ...Part 5 Electrical Diagrams ...