3-7
Part 3: Adjustment
2.5 Signal Level Adjustment
Measuring equipment ............Oscilloscope
Input mode ...........................Computer
Input signal ...........................16-step gray scale
Enter the service mode.
Adjust part A of signal waveform at each test point to the following value with the
/- button.
Item No.
Test point
Adjustment value
10
TP-R1
10V ± 0.1V p-p
11
TP-G1
10V ± 0.1V p-p
12
TP-B1
10V ± 0.1V p-p
Fig. 3-4
2.6 Flicker Adjustment
Input mode ...........................Computer
Input signal ...........................1-dot line computer signal
Enter the service mode.
Minimize flicker on each color screen with the /- button.
Item No.
Screen
19
Red screen
20
Green screen
21
Blue screen
A