LV-7575 Expand Serial Command Functional Specifications
40/71
9.4.4
CR_TINT Command
Command “CR_TINT”
[CR]
Details
Get user controlled value of Tint
Acceptable “000_%1”
[CR]
%1
“000 – 063”
Response
Unacceptable
“Error Code” [CR] --- When command is not available in the given
condition (such as being selected input).
“?” [CR] --- When unknown command is received
9.4.5
CR_SHARP Command
Command “CR_SHARP”
[CR]
Details
Get user controlled value of Sharpness
Acceptable “000_%1”
[CR]
%1
“000 – 031”
Response
Unacceptable “?”
[CR]
9.4.6
CR_GAMMA Command
Command “CR_GAMMA”
[CR]
Details
Get user controlled value of Gamma
Acceptable “000_%1”
[CR]
%1
“000 – 015”
Response
Unacceptable “?”
[CR]
9.4.7
CR_WBAL-R Command
Command “CR_WBAL-R”
[CR]
Details
Get user controlled Red value of White Balance
Acceptable “000_%1”
[CR]
%1
“000 – 063”
Response
Unacceptable “?”
[CR]
9.4.8
CR_WBAL-G Command
Command “CR_WBAL-G”
[CR]
Details
Get user controlled Green value of White Balance
Acceptable “000_%1”
[CR]
%1
“000 – 063”
Response
Unacceptable “?”
[CR]
9.4.9
CR_WBAL-B Command
Command “CR_WBAL-B”
[CR]
Details
Get user controlled Blue value of White Balance
Acceptable “000_%1”
[CR]
%1
“000 – 063”
Response
Unacceptable “?”
[CR]