![background image](http://html1.mh-extra.com/html/canon/lv-7392a/lv-7392a_command-list_4123658063.webp)
LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/LV-8227M
Expand Serial Command Functional Specifications
-57-
9.10 Sound Status Read Command
9.10.1 CR_VOLUME Command
Command “CR_VOLUME”[CR]
Details
Get Volume value of user control
Response
Acceptable “000_%a”[CR]
%a “000”~“063”
Unacceptable “Error Code” [CR]
9.10.2 CR_MUTE Command
Command “CR_MUTE”[CR]
Details
Get sound mute setting status
Response
Acceptable “000_%a”[CR]
%a
“ON” -------------------- Sound Mute is ON
“OFF” ------------------- Sound Mute is OFF
Unacceptable “Error Code” [CR]
9.10.3 CR_MIC Command
Command
“CR_MIC”[CR]
Details
Get setting status of MIC
Response
Acceptable
“000_%1”[CR]
%1
“ON” -------------------- MIC is ON
“OFF” ------------------- MIC is OFF
Unacceptable
“Error Code” [CR]
9.10.4 CR_MICGAIN Command
Command
“CR_MICGAIN”[CR]
Details
Get MIC gain value of user control
Response
Acceptable
“000_%a”[CR]
%a
“000” ~ “063”
Unacceptable
“Error Code” [CR]
9.10.5 CR_STANDBYMICOUT Command
Command
“CR_STANDBYMICOUT”[CR]
Details
Get setting status ofStandby MIC out
Response
Acceptable
“000_%1”[CR]
%1
“ON” --------------------
Standby MIC out
is ON
“OFF” -------------------
Standby MIC out
is OFF
Unacceptable
“Error Code” [CR]