Basic Serial Command Functional Specification
Page 18 of 19
7.3.10. “24” [CR]
Status: Processing Cooling down by power save
Cooling down by the Power Management function in the Setting menu.
The control command is invalid.
This Cooling down by Power save moves to Power save after the cooling down time.
Status: No signal Cooling Down by Power Save
Power Save
Response:
“00” “24” “04”
After 5 minutes with no signal After about 90
seconds
7.3.11. “04” [CR]
Status: Power Save
The status is Power Save by the Power management function in setting menu.
7.4. Input Mode Read Command
Command
“CR1” [CR]
Detail
Get selected Input No.
Acceptable
“%1” [CR]
%1
“1” = Computer 1
“2” = Computer 2
“3” = Video
Response
Unacceptable “?” [CR]
7.5. Lamp Time Read Command
Command
“CR3” [CR]
Detail
Get total lamp running hours.
Acceptable
“%1” [CR]
%1
Show as 4 digits
Ex.: “0410” [CR] ---- 410 hours
Response
Unacceptable “?” [CR]
7.6. Setting Read Command
Command
“CR4” [CR]
Detail
Get setting status for screen such as Ceiling / Rear.
Acceptable
“%1” [CR]
%1
“11” = Normal Screen Setting
“10” = Top and Bottom reversal setting (Rear
&
Ceiling On)
“01” = Left and Right reversal setting (Rear On)
“00” = Top / Bottom and Left / Right reversal setting (Ceiling On)
Response
Unacceptable “?” [CR]