![Canon Laser Shot LBP-5100 Service Manual Download Page 66](http://html.mh-extra.com/html/canon/laser-shot-lbp-5100/laser-shot-lbp-5100_service-manual_2553177066.webp)
Chapter 2
2-32
2.6.2 Various Control Mechanisms
2.6.2.1 Fixing Temperature Control
2.6.2.1.1 Fixing Temperature Control
0010-6160
LBP5000
The machine monitors the surface temperature of the fixing heater, and controls the drive signal of the fixing heater so that the temperature will be identical to the
target temperature.
F-2-36
The temperature of the fixing heater is checked by 2 thermistors: main thermistor (TH1), sub thermistor (TH2).
TH1 is used for printing temperature detection and sheet-to-sheet temperature control, while TH2 is used to check for edge overheating.
The CPU (IC7) on the DC controller PCB monitors the voltage of these 2 thermistors, and generates the fixing heater drive signal (FSRD) according to the level of
the voltage.
The machine's fixing temperature control mechanism uses the following 5 sequences of operation:
1. Initial Multiple Rotation Temperature Control
The machine executes initial multiple rotation temperature control to prevent tears in the fixing film by melting the grease on the inner side of the film at power-
on for smoother belt movement.
If the reading of the sub thermistor is lower than 55 deg C at power-on, the CPU turns on the fixing heater for a specific period of time before it starts the fixing/
delivery motor.
2. Start-Up Temperature Control
The machine executes start-up temperature control to determine the start-up temperature for the fixing heater to suit the reading of the main thermistor detected
when turning on the heater. If the heater is turned on within 40 sec after the end of the previous print job, the previous printing temperature is used for the
upcoming print job.
3. Printing Temperature Control
The machine executes printing temperature control so that the temperature of the fixing heater will be identical to the target temperature during printing.
In continuous printing mode, the machine changes the target temperature in stages according to the specified number of prints
4. Sheet-to-Sheet Temperature Control
The machine executes sheet-to-sheet temperature control to prevent overheating of the fixing pressure roller between sheets in continuous mode (low-speed
mode). The temperature of the fixing heater is lowered between sheets.
The sheet-to-sheet temperature, further, is varied depending on the distance between sheets and the type of paper used.
5. Throughput Reduction Control
The machine executes throughput reduction control to prevent overheating of the edges of the fixing heater during continuous printing on narrow paper.
If the reading of the sub thermistor exceeds a specific level in continuous printing, if the paper width sensor does not detect paper, or if the width of paper is less
than 195 mm, the machine will increase the distance between sheets to decrease throughput
T-2-5
Mode
Temperature
control 1
Temperature
control 2
Temperature
control 3
Temperature
control 4
Temperature
control 5
Plain paper
Number of sheets passed
1-5
6-17
18-37
38-73
74-
Initial rotation temperature
199
179
167
161
154
Printing temperature
194
189
182
176
169
Sheet-to-sheet temperature
194
184
177
171
164
Heavy paper 1
Number of sheets passed
1-2
3-6
7-13
14-25
26-
Initial rotation temperature
160
153
150
145
140
Printing temperature
165
163
160
155
150
Sheet-to-sheet temperature
155
153
150
145
140
Fixing heater (H100)
Thermal fuse (FU100)
Fixing film unit
Main thermistor
(TH1)
Fixing heater
safety circuit
Low-voltage power supply unit
IC7
CPU
DC controller PCB
Sub thermistor
(TH2)
FSRD
Fixing unit
SUBTH
MAINTH
RLD
RLD+
RLD-
ZEROX
Fixing control circuit
+24V
+3.3V
RL901
Relay drive
circuit
Fixing heater
drive circuit
Zero crossing
circuit
+3.3V
Summary of Contents for Laser Shot LBP-5100
Page 1: ...Feb 26 2007 Service Manual LBP5000 5100 Series ...
Page 2: ......
Page 6: ......
Page 14: ...Contents ...
Page 15: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 16: ......
Page 18: ......
Page 28: ......
Page 29: ...Chapter 2 TECHNICAL REFERENCE ...
Page 30: ......
Page 33: ...Contents 2 8 3 2 Overview of the Block 2 39 ...
Page 34: ......
Page 74: ...Chapter 2 2 40 IC12 Logic IC Converts voltage levels Notation Name Description ...
Page 75: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Page 76: ......
Page 80: ......
Page 122: ......
Page 123: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Page 124: ......
Page 126: ......
Page 132: ......
Page 133: ...Chapter 5 TROUBLESHOOTING ...
Page 134: ......
Page 136: ......
Page 141: ...Chapter 5 5 5 F 5 9 ...
Page 142: ...Chapter 5 5 6 F 5 10 ...
Page 149: ...Chapter 6 APPENDIX ...
Page 150: ......
Page 152: ......
Page 161: ...Feb 26 2007 ...
Page 162: ......