Chapter 5
5-10
0000
Particulars
The revolution of the main motor fails to reach a specific value within 100 msec
after the main motor is started.
Cause
The main motor is faulty. The DC controller PCB is faulty.
- Replace the main motor.
- Replace the DC controller.
0001
Particulars
The revolution of the main motor reached a specific value, but thereafter has
deviated continuously for 100 msec or more.
Cause
The main motor is faulty. The DC controller is faulty.
E020
The density sensor is faulty.
Particulars
The amount of light fails to reach a specific value when the density of the image
is being checked.
Cause
The density sensor is soiled. The density sensor is faulty. The DC controller PCB
is faulty. The toner cartridge is faulty.
- Replace the ETB unit.
- Suspect a high-voltage contact is faulty. (Check the contacts
between the high-voltage contact of each color to the high-voltage
PCB.)
- Replace the DC controller PCB.
- Replace the toner cartridge.
E024
The toner level sensor is faulty.
0000
Particulars
The light-receiving segment continues to receive light while the stirring plate of
yellow cartridge rotates 5 times.
Cause
The memory controller PCB is faulty. The DC controller PCB is faulty. The toner
cartridge is faulty.
- Replace the toner cartridge.
- Replace the memory controller PCB.
- Replace the DC controller PCB.
0001
Particulars
The light-receiving segment continues to receive light while the stirring plate of
mazenta rotates 5 times.
Cause
The memory controller PCB is faulty. The DC controller PCB is faulty. The toner
cartridge is faulty.
0002
Particulars
The light-receiving segment continues to receive light while the stirring plate of
cyan cartridge rotates 5 times.
Cause
The memory controller PCB is faulty. The DC controller PCB is faulty. The toner
cartridge is faulty.
0003
Particulars
The light-receiving segment continues to receive light while the stirring plate of
black cartridge rotates 5 times.
Cause
The memory controller PCB is faulty. The DC controller PCB is faulty. The toner
cartridge is faulty.
E052
The duplexing unit connection is faulty.
Particulars
The duplexing unit connection is faulty.
Cause
The duplexing driver PCD is faulty. The DC controller PCB is faulty.
- Confirm the connection between the DC controller PCB and the
duplexing driver.
- Replace the duplexing driver PCB.
- Replace the DC controller PCB.
E066
The environment sensor is faulty.
Particulars
The output of the environment sensor is faulty.
Cause
The environment sensor is faulty. The DC controller PCB is faulty.
- Replace the environment sensor.
- Replace the DC controller PCB.
E100
The scanner motor is faulty. The laser unit is faulty. The beam detector is faulty.
0000
Particulars
The yellow scanner mechanism is faulty.
Cause
The laser scanner unit is faulty. The DC controller PCB is faulty.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
0001
Particulars
The magenta scanner mechanism is faulty. The DC controller PCB is faulty.
0002
Particulars
The cyan scanner mechanism is faulty.
The laser scanner unit is faulty. The DC controller PCB is faulty.
0003
Particulars
The black scanner mechanism is faulty.
Cause
The laser scanner mechanism is faulty. The DC controller PCB is faulty.
E110
The pseudo-BD correction is faulty.
Particulars
The scanner failed to be ready within 3 seconds after the pseudo-BD correction
control started.
Cause
The laser scanner unit is faulty. The DC controller PCB is faulty.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
E194
The CPR sensor is faulty.
Particulars
The color displacement detection pattern is not recognized. The result of
measurement is outside a specific range.
Cause
The color displacement sensor is soiled. The color displacement sensor is faulty.
The DC controller PCB is faulty. The toner cartridge is faulty.
- Replace the ETB unit.
- Suspect that a high-voltage contact is faulty. (Check the contacts
from the high-voltage contact of each color to the high-voltage
PCB.)
- Replace the DC controller.
- Replace the toner cartridge.
E196
DCON ROM abnormality
Code
Description
Remedial action
Summary of Contents for Laser Shot LBP-5100
Page 1: ...Feb 26 2007 Service Manual LBP5000 5100 Series ...
Page 2: ......
Page 6: ......
Page 14: ...Contents ...
Page 15: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 16: ......
Page 18: ......
Page 28: ......
Page 29: ...Chapter 2 TECHNICAL REFERENCE ...
Page 30: ......
Page 33: ...Contents 2 8 3 2 Overview of the Block 2 39 ...
Page 34: ......
Page 74: ...Chapter 2 2 40 IC12 Logic IC Converts voltage levels Notation Name Description ...
Page 75: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Page 76: ......
Page 80: ......
Page 122: ......
Page 123: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Page 124: ......
Page 126: ......
Page 132: ......
Page 133: ...Chapter 5 TROUBLESHOOTING ...
Page 134: ......
Page 136: ......
Page 141: ...Chapter 5 5 5 F 5 9 ...
Page 142: ...Chapter 5 5 6 F 5 10 ...
Page 149: ...Chapter 6 APPENDIX ...
Page 150: ......
Page 152: ......
Page 161: ...Feb 26 2007 ...
Page 162: ......