Chapter 7
7-95
(3) How to enter user name
F-7-51
[1] Entry filed (24 one-byte characters)
- It is the same as the entering method of proxy server address.
(4) How to enter password
F-7-52
[1] Entry filed (24 one-byte characters)
- If a password has already been set, when you press the
or
key at any cursor position, all the "*" will disappear and the first letter will be entered as the first
character.
- Entered characters are visible until you press OK key. Once entering into the menu again, they will be changed to "*".
- Other information is the same as the entering method of proxy server address.
3.2 e-RDS settings
1) Enter the service mode.
- Turn off the printer power.
- Turn on the power while pressing the [Load] key and [Navigate] key.
* Keep pressing the above keys until "Initializing" is displayed.
- "S" appears at the top right of the display.
- Press the
or
key to choose the [Set./Adj. Menu]and press the [OK] key.
* "SERVICE MODE" appears in the menu list and the MESSAGE LED flashes.
- Press the
key or
key to choose "SERVICE MODE" and press the [OK] key.
2) Set the following e-RDS setting items No.1-4.
(If the result of the communication test (COM-TEST) is "NG", execute setting items No.5-6 to solve the problem.)
T-7-178
3.3 Service Mode Menu Tree
No.
Item
Type
Description
1
E-RDS SWITCH
2 bytes
OFF : Disable/ ON : Enable e-Maintenance/ imageWARE Remote system to send device information,
meter data, and error statuses to the UGW.
Default value is OFF (not in use)
2
UGW-ADDRESS
129 bytes
(NULL
included, SJIS
not allowed)
The UGW address by default : https://a01---.
The complete address is not provided in this document for security reason.
3
UGW-PORT
4 bytes
The UGW Port Number by default : 443
Validation : 1-65535
4
COM-TEST
To perform Communication test with UGW and set "OK!"/ "NG!" as the result.
5
COM-LOG
Detailed communication data log
Switches to display time when error occurred, error code, and error data up to now.
Max 30 loggings retained.
Max 128 characters (not containing NULL) for Error information.
6
ERDS-DAT
Initialize e-RDS setting data
Proxy User
User Name Canon
[a]
: S e l e c t
S t o p
: D e l e t e
N a v i
: a -> A -> 1
[ O K : S e t ]
[1]
Proxy Password
[a]
: S e l e c t
S t o p
: D e l e t e
N a v i
: a -> A -> 1
[ OK : S e t ]
[1]
Summary of Contents for imagePROGRAF iPF6200
Page 1: ...Mar 7 2011 Service Manual iPF6000 series ...
Page 2: ......
Page 6: ......
Page 14: ...Contents ...
Page 15: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 16: ......
Page 174: ...Chapter 1 1 156 ...
Page 175: ......
Page 176: ......
Page 177: ...Chapter 2 TECHNICAL REFERENCE ...
Page 178: ......
Page 276: ......
Page 277: ...Chapter 3 INSTALLATION ...
Page 278: ......
Page 280: ......
Page 305: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Page 306: ......
Page 308: ......
Page 402: ......
Page 403: ...Chapter 5 MAINTENANCE ...
Page 404: ......
Page 406: ......
Page 421: ...Chapter 6 TROUBLESHOOTING ...
Page 422: ......
Page 507: ...Chapter 7 SERVICE MODE ...
Page 508: ......
Page 510: ......
Page 643: ......
Page 644: ......
Page 645: ...Chapter 8 ERROR CODE ...
Page 646: ......
Page 648: ......
Page 690: ......
Page 691: ...Mar 7 2011 ...
Page 692: ......