4-21
CHAPTER 4 SERVICE MODE
<HV-STS>
Indicates the measurements of voltage and current.
Level 3
PRIMARY
BIAS
TR-V
Remarks
Unit: µA; about 200 µA
Unit: V
Unit: V
Description
Current applied to the primary charging roller.
Developing bias Dc value
ATVC detection voltage
If the level of 'TR-V' is 30 to 100, transfer is
assumed to be normal.