4-79
Status 35 (feeding assembly trouble status in detail)
Bit
Meaning
1
0
0
Parity bit (odd number)
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Main motor trouble
Out of order
Normal
7
0
Table 4-30
[Bit 6]
When the ready signal does not come continuously at 0.1 seconds after the main motor
drive starts, this becomes 1.
When the ready signal is continuous at 0.1 seconds after the main motor drive has
stopped, this becomes 1.
CHAPTER 4 SERVICE MODE