V. MALFUNCTION TROUBLESHOOTING
N-1 Power ON failure
<Possible causes>
1. The duplexing unit is not set correctly.
Action:
Re-set it.
2. Poor connection with the connector of 24 V supply line.
Action:
Reconnect the connector J2001 on the duplexing driver PCB correctly.
3. The duplexing driver PCB failure
Action:
Replace it.
N-2 Side registration motor failure
<Possible causes>
1. Poor connection with the connector of the SIDE REGISTRATION MOTOR DRIVE signal line.
Action:
Reconnect the connector J2005 on the duplexing driver PCB correctly.
2. The side registration motor failure
Action:
Replace it.
3. The duplexing driver PCB failure
Action:
Replace it.
N-3 Duplexing unit motor failure
<Possible causes>
1. Poor connection with the connector of the DUPLEXING MOTOR DRIVE signal line.
Action:
Reconnect the connector J2004 on the duplexing driver PCB correctly.
2.
The duplexing unit motor failure
Action:
Replace it.
3. The duplexing driver PCB failure
Action:
Replace it.
N-4 Reversing roller release solenoid failure
<Possible causes>
1. Poor connection with the connector of the REVERSING ROLLER RELEASE SOLENOID
DRIVE signal line.
Action:
Reconnect the connector J2009 on the duplexing driver PCB correctly.
2. The reversing roller release solenoid failure
Action:
Disconnect the connector J2009 on the reversing roller release solenoid. Measure
the resistance between the connector J2009-1 and J2009-2 of the cable.
If it is not about 50
Ω
, replace the reversing roller release solenoid.
3. The duplexing driver PCB failure
Action:
Replace it.
4 - 7
CHAPTER 4
Summary of Contents for DU-82
Page 8: ......
Page 14: ......
Page 26: ......
Page 38: ...V MOTORS A Locations Duplexing unit motor Side registration motor Figure 3 5 1 3 12 CHAPTER 3 ...
Page 40: ...VI ELECTRICAL PARTS A Locations Duplexing driver PCB Figure 3 6 1 3 14 CHAPTER 3 ...
Page 42: ......
Page 44: ......
Page 58: ......
Page 59: ...APPENDIX I GENERAL TIMING CHART A 1 II GENERAL CIRCUIT DIAGRAM A 2 III LIST OF SIGNALS A 3 ...
Page 60: ......
Page 64: ......