1.3 Service Conditions
When you carry out the electrical, optical service adjustment or repairing with cabinet
top removal, it should be done under the service conditions listed below. If you can not
keep the one of following conditions, the projector turns off automatically by operating
the protection circuit.
To set the Fan Control to maximum, follow the Fan Control Setting Procedure below;
Fan Control Setting Procedure
1. Enter to the service mode.
2. Select adjustment item no.<29> and change data value to <0> to <1>. Now the cooling
fans operate in maximum.
3. Exit from the service mode.
After finishing the works, restore the service data to <0> following to the steps 1 to 3.
*Please refer to the “Service Adjustment Menu Operation” described on page 23 for how
to entering the service mode and changing the service data.
Part 3: Adjustment
3-4
Service Conditions:
Operating Temperature
: 41°F ~ 81°F (5°C ~ 30°C)
Fans Control : Maximum
AC Power Supply
: 100 ~ 120V or 200V ~ 240V
Summary of Contents for D78-5132
Page 2: ......
Page 3: ...CANON Multimedia Projector LV 7105U D78 5132 LV 7105E D78 5133 SERVICE SMANUAL ...
Page 10: ......
Page 11: ...Part 1 General Information ...
Page 12: ......
Page 33: ...Part 2 Repair Information ...
Page 34: ......
Page 54: ......
Page 55: ...Part 3 Adjustment ...
Page 56: ......
Page 77: ...Part 4 Troubleshooting ...
Page 78: ......
Page 81: ... Memo Part 4 Troubleshooting 4 3 ...
Page 94: ...Part 4 Troubleshooting 4 16 M62358FP DAC IC431 CXD3503R White Uniformity Compensation IC471 ...
Page 96: ...Part 4 Troubleshooting 4 18 IDT71V016S RAM IC811 CXA2016S Sync Separator IC1021 ...
Page 97: ...Part 4 Troubleshooting 4 19 MC10H351ML IC1501 LM76CHMX Thermal Sensor IC1831 IC1832 ...
Page 99: ...Part 4 Troubleshooting 4 21 TC4053BF Switching IC5001 SAA7114H Digital Video Processor IC5101 ...
Page 100: ...Part 4 Troubleshooting 4 22 ...
Page 101: ...Part 5 Parts Catalog ...
Page 102: ......
Page 104: ......
Page 117: ......
Page 118: ...Part 6 Electrical Diagrams ...
Page 119: ......