Enter 32 End
*/$%ENTR* *ZEND*
4. General Setting
4-1-9 Good Read Beep Freq
When decoding successfully, it will make a sound, and you can use this setting
to set Beep Frequency.
*6IO+*
Configuration Range Unit
Default Setting
100 ~ 3500Hz
100Hz
2700 Hz
4-1-10 Good Read Beep Time
When decoding successfully, it will make a sound, you can use this setting to
set the duration of Beep Time.
*7IP+*
Configuration Range Unit
Default Setting
10 ~ 2550ms
10ms
100 ms
Procedure
(A) Scan “Enter” barcode
(B) Scan “Good Read Beep Freq” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
Procedure
(A) Scan “Enter” barcode
(B) Scan “Good Read Beep Time” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
4-1-9 Good Read Beep Freq
4-1-10 Good Read Beep Time