background image

03 GB

The hob may be installed in any worktop which is heat resistant to a
temperature of 100°C, and has a thickness of 25-45 mm. The
dimensions of the insert to be cut out of the worktop are in shown in

Figure 2.

When there is an accessible space between the built-in hob and the
cavity below, a dividing wall made of insulating material should be
inserted (wood or a similar material)

(Figure 3).

If the hob is fitted next to a cabinet on either side, the distance between
the hob and the cabinet must be at least 15 cm; while the distance
between the cut out and the rear wall must be at least 7 cm.
The distance between the hob and any other unit or appliance above it
(e.g. An extractor hood) must be no less than 70 cm

.

(Figure 4)

Metal objects in the drawer may reach high temperatures due to
air recirculation. It is therefore recommended to use an
intermediate wood panel.
Important - The diagram in figure 1 shows how the sealant should
be applied.

The Hob unit is fitted by attaching the Fixing Clamps supplied, using
the holes at the base of the unit.
When a 60 cm hob or a 75 cm hob is fitted over a built in oven, the latter
must be fan cooled.

1.1 BUILDING IN

1.2. SUITABLE LOCATION

This appliance must be installed in accordance with the regulations in
force and only used in a well ventilated space. Read the instructions
before installing or using this appliance.
A gas-powered cooking appliance produces heat and humidity in the
area in which it is installed. For this reason you should ensure good
ventilation either by keeping all natural air passages open or by
installing an extractor hood with an exhaust flue. Intensive and
prolonged use of the appliance may require extra ventilation, such as
the opening of a window or an increase in speed of the electric fan, if
you have one.
If a hood can not be installed, an electric fan should be fitted to an
outside wall or window to ensure that there is adequate ventilation.
The electric fan should be able to carry out a complete change of air in
the kitchen 3-5 times every hour. The installer should follow the
relevant national standards.

2. ELECTRICAL CONNECTION

(FOR U.K. ONLY)

Warning - this appliance must be earthed

This appliance is designed for domestic use only. Connection to the main
supply must be made by a competant electrician, ensuring that all current
regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a
3 pin 13 amp plug/socket is not suitable. A double pole switch must be
provided and the circuit must have appropriate fuse protection.
Further details of the power requirement of the individual product will
be found in the users’ instruction and on the appliance rating plate. In
the case of built-in product you are advised, should you wish to use a
longer cable than the one supplied, that a suitably rated heat resistant
type must be used.

The wiring must be connected to the mains supply as follows:

CONNECT

TO SPUR TERMINAL

Green & Yellow Wire

Earth Connection

Blue Wire

Neutral Connection

Brown Wire

Live Connection

Note:

We do not advocate the use of earth leakage devices with

electric cooking appliances installed to spur points because of the
«nuisance tripping» which may occur. You are again reminded that the
appliance must be correctly earthed, the manufacturer declines any
responsibility for any event occurring as a result of incorrect electrical
installation.

2.1. ELECTRICAL CONNECTION

Check the data on the rating plate, located on the outside of the unit, to
ensure that the supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not complied
with, the Manufacturer will not be responsible for any damage caused to
persons or property. If a plug is not already attached, fit a plug
appropriate to the load indicated on the rating plate. The earth wire is
coloured yellow/green. The plug should always be accessible.
Where the Hob is connected direct to the electricity supply, a circuit
breaker must be fitted.
If the power supply cord is damaged this is to be replaced by a qualified
engineer so as to prevent any potential risk.
The earth wire ( green and yellow coloured ) must be at least 10 mm
longer than the live and neutral wires.
The section of the cable used must be of the correct size in relation to
the absorbed power of the hob.
Please check rating plate for the power details and ensure that the
power supply cord is of the type 3x0.75 mm² H05 V2V2-F.

LIVE
EARTH
NEUTRAL

L

N

Power Cable

Brown Wire

Green/Yellow Wire
Blue Wire

Mains Supply

If an appliance is not fitted with a supply cord and a plug, or with other
means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under
overvoltage category III conditions, the instructions shall state that
means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.

1. INSTRUCTIONS FOR THE INSTALLER

INSTALLING A DOMESTIC APPLIANCE CAN BE A COMPLICATED OPERATION WHICH IF NOT CARRIED OUT CORRECTLY, CAN SERIOUSLY
AFFECT CONSUMER SAFETY. IT IS FOR THIS REASON THAT THE TASK SHOULD BE UNDERTAKEN BY A PROFESSIONALLY QUALIFIED
PERSON WHO WILL CARRY IT OUT IN ACCORDANCE WITH THE TECHNICAL REGULATIONS IN FORCE. IN THE EVENT THAT THIS ADVICE IS
IGNORED AND THE INSTALLATION IS CARRIED OUT BY AN UNQUALIFIED PERSON, THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR ANY TECHNICAL FAILURE OF THE PRODUCT WHETHER OR NOT IT RESULTS IN DAMAGE TO GOODS OR INJURY TO INDIVIDUALS.

These instructions are for qualified personnel, installation of
equipment must be in line with the relevant national standard.

(For

U.K. only: by law the gas installation\commissioning must be
carried out by a "Gas Safe" installer)

All work must be carried out with the electricity supply disconnected.
The rating plate on the hob shows the type of gas with which it is
designed to be used. Connection to the mains gas supply or gas
cylinder should be carried out after having checked that it is regulated
for the type of gas with which it will be supplied. If it is not correctly
regulated see the instructions in the following paragraphs to change
gas setting.
For liquid gas (cylinder gas) use pressure regulators which comply
with the relevant national standards.
Use only pipes,washers and sealing washers which comply with the
relevant national standards.

For some models a conic link is furnished to outfit for the installation in
the countries where this type of link is obligatory; in picture 7 it is
pointed out how to recognize the different types of links (CY =
cylindrical, CO = conic). In every case the cylindrical part of the link
has to be connected to the hob.
When connecting the hob to the gas supply via use offlexible hoses
please ensure that the maximum distance covered by the hose does
not exceed 2 metres.
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit (e.g. a drawer) and does
not pass through any space where it may become crushed/ kinked or
damaged in any way.

To prevent any potential damage to the hob please carry out the
installation following this sequence (picture ):

5

1)As illustrated, assemble parts in sequence:

A: 1/2 Male Adaptor Cylindirical
B: 1/2 Seal
C: 1/2 Female Gas Adaptor Conical-Cylindirical or

Cylindirical-Cylindirical

2.2. GAS CONNECTION

Summary of Contents for HHG7WL5WC5X NL

Page 1: ......

Page 2: ... for the load indicated on the tag and must be having the earth contact connected and in operation The earth conductor is yellow green in color This operation should be carried out by a suitably qualified professional In case of incompatibility between the socket and the appliance plug ask a qualified electrician to substitute the socket with another suitable type The plug and the socket must be c...

Page 3: ...earthing system By Law this appliance must be earthed If this regulation is not complied with the Manufacturer will not be responsible for any damage caused to persons or property If a plug is not already attached fit a plug appropriate to the load indicated on the rating plate The earth wire is coloured yellow green The plug should always be accessible Where the Hob is connected direct to the ele...

Page 4: ...be carried out only by qualified Service Engineers 2 Tighten the joints with the spanner remembering to twist the pipes into position 3 Attach fitting C to mains gas supply using rigid copper pipe or flexible steel pipe IMPORTANT carry out a final check for leaks on the pipe connections using a soapy solution NEVER USE A FLAME Also make sure that the flexible pipe cannot come into contact with a m...

Page 5: ...l relevant European safety health and environmental requirements which are applicable in legislation for this product 5 AFTERCARE Before calling out a Service Engineer please check the following that the plug is correctly inserted and fused that the gas supply is not faulty If the fault cannot be detected Switch off the appliance and call the After Service Centre DO NOT TAMPER WITH THE APPLIANCE B...

Page 6: ...tée par du personnel qualifié En cas d incompatibilité entre la prise d alimentation et la fiche du câble de l appareil demander à un électricien professionnel de remplacer la prise d alimentation par un dispositif compatible La CONSIGNES DE SÉCURITÉ fiche du câble d alimentation et la prise d alimentation doivent être conformes aux normes en vigueur dans le pays d installation Il est possible de ...

Page 7: ...continuité de la terre de l installation avant de procéder au raccordement Notre responsabilité ne saurait être engagée pour tout incident ou ses conséquences éventuelles qui pourraient survenir à l usage d un appareil non relié à la terre ou relié à une terre dont la continuité serait défectueuse Si une prise n est pas déjà fournie installer une prise appropriée pour la charge indiquée sur la pla...

Page 8: ...e telle manière que la flamme ne chevauche pas le fond de la casserole Les récipients à fond concave ou convexe ne doivent pas être utilisés ATTENTION Si un brûleur est accidentellement éteint tournez le bouton vers la position fermée et ne pas tenter de relancer pendant au moins 1 minute Si au fil des années les robinets de gaz deviennent raides il est nécessaire de les lubrifier Cette opération ...

Page 9: ......

Page 10: ...collegato e funzionante Il conduttore di terra è giallo verde Questa operazione deve essere eseguita solo da un tecnico adeguatamente addestrato In caso di ISTRUZIONI DI SICUREZZA i n c o m p a t i b i l i t à t r a p r e s a e s p i n a dell elettrodomestico richiedere ad un tecnico specializzato di sostituire la presa con un altra di tipo compatibile La spina e la presa devono essere conformi al...

Page 11: ...ognerà predisporre anche un salvavita Se il cavo di alimentazione è danneggiato dovrà essere sostituito da personale qualificato in modo da prevenire qualsiasi potenziale rischio Il cavo di messa a terra di color verde giallo deve essere più lungo di almeno 10 mm rispetto ai cavi neutro e fase La sezione del cavo usato deve essere delle giuste dimensioni in base all assorbimento dell apparecchio S...

Page 12: ...W 1 00 1 75 2 70 G20 20 mbar Metano 95 l h 167 l h 257 l h G30 28 30 mbar LPG 73 g h 127 g h 196 g h DC 5 kW MONO 16 26 5 NG 4 6 LPG 476 l h 334 g h AVVISI GENERICI Per risultati migliori la dimensione delle pentole deve seguire la dimensione del bruciatore come mostrato qui a seguito TabellaA Per contenitori più piccoli il bruciatore gas può essere regolato in modo che la fiamma non superi la pas...

Page 13: ...2 220 240V 50 60Hz 3 1 Sì 745x505x42 UH75MF Sì 1 5Gas L3 4 1 AUX 2SR R DC 2 1 1 NG 12 20 kW LPG 11 80 kW 1162 l h 8 7 g h 5 4 MANUTENZIONE E PULIZIA Prima di pulire il piano cottura assicurarsi che l apparecchio si sia raffreddato La pulizia e la manutenzione non dovrebbero essere fatte da bambini senza supervisione Rimuovere la spina dalla presa corrente o se connessa direttamente all alimentazio...

Page 14: ...op het etiket staat aangegeven en moet een goed werkende aarding hebben De aardgeleider is groen geel gekleurd Dit moet worden gedaan door een gekwalificeerd VEILIGHEIDSAANWIJZINGEN vakman In het geval van incompatibiliteit tussen het stopcontact en de stekker van het apparaat moet u een gekwalificeerd elektricien vragen om het stopcontact te vervangen door een ander geschikt stopcontact De stekke...

Page 15: ...LUITEN Het aansluiten van het apparaat op het gasnet of gasflessen dient te gebeuren volgens de wettelijk geldende voorschriften Speciale aandacht zal worden besteed aan voorzieningen voor ventilatie Alle installatie werkzaamheden dienen te worden gedaan met de stroom afgekoppeld van het stroomnet Op het typeplaatje is aangegeven voor welke type gas dit apparaat geschikt is De gasaansluiting dient...

Page 16: ...am met een deksel of een branddeken Tijdens de werking van de kookplaat kunnen bereikbare delen zeer heet worden dus het is aan te raden om jonge kinderen te verwijderen Kinderen moeten onder toezicht worden gehouden zodat ze niet met het apparaat gaan spelen 3 1 GEBRUIK VAN DE GASBRANDERS Voor optimaal gebruik van de branders raden wij u aan pannen te gebruiken die bij de branders passen Om de br...

Page 17: ... AUX 2SR R DC 2 1 1 NG 12 20 kW LPG 11 80 kW 1162 l h 8 7 g h 5 4 ONDERHOUD EN REINIGEN Voordat u gaat demonteren of schoonmaken dient u de stroomvoorziening af te sluiten door de stekker uit het stopcontact te halen of de stroomtoevoer via de zekering af te sluiten Zorg ervoor dat het apparaat volledig is afgekoeld Reinig de geëmailleerde verchroomde en geverfde delen met handwarm water en met ee...

Page 18: ...Last geeignet sein und über einen funktionsfähigen Schutzkontakt verfügen Der SICHERHEITSHINWEISE Schutzleiter hat die Farbe Gelb Grün Diese Arbeit darf nur von qualifiziertem Personal durchgeführt werden Falls Steckdose und Gerätestecker nicht kompatibel sind wenden Sie sich an einen qualifizierten Elektriker um einen entsprechenden Austausch vorzunehmen Stecker und Steckdose müssen den geltenden...

Page 19: ...vicefall vom Kundendienst benötigt werden Überprüfen Sie dass die Netzspannung und die Leistung für den Betrieb des Gerätes geeignet sind Vor dem elektrischen Anschluss ist die einwandfreie Erdung der elektrischen Hausinstallation zu prüfen Die Erdung des Gerätes ist gesetzlich vorgeschrieben Der Hersteller weist jede Verantwortung für Sach oder Personenschäden zurück die auf fehlende bzw mangelha...

Page 20: ...se Gaskochmulde ist mit einer elektronischen Zundung zum Zunden des Brennersausgestattet Gehen Sie folgendermasen vor umdie Brenner zuzunden Den Reglerknopf eindrucken und gegen den Uhrzeigersinn auf das Größere Flammensymbol oder in Position 9 drehen und nach der Bei Pfannen oder Töpfen mit kleinem Durchmesser regulieren Sie die Leistung des Brenners so dass die Flamme den Topf bzw Pfannenboden n...

Page 21: ... einmal nicht ordnungsgemäß funktionieren kontrollieren Sie bitte folgendes bevor Sie den technischen Kundendienst rufen überprüfen Sie dass das Gerät stromversorgt ist überprüfen Sie dass die Gaszufuhr in Ordnung ist Sollte die Ursache für die Funktionsstörung nicht ermittelt werden können trennen Sie das Gerät vom Stromnetz und rufen Sie den Kundendienst Unternehmen Sie nichts auf eigene Faust D...

Page 22: ... 60 75 35 mm 25 45 mm min 5 mm min 10 mm min 50 mm 25 45 mm min 5 mm Figure 3 min 50 mm 35 mm min 10 mm min 50 mm min 50 mm 560 mm 480 mm min 70 mm min 600 mm min 50 mm min 170 mm 60 cm min 250 mm 75 cm Figure 2 CONICAL CYLINDRICAL CYLINDRICAL Min 70 cm Figure 4 Figure 8 ...

Page 23: ... 54 57 6 UH75MF 4 1 L3 SINGLE BURNER EFFICIENCY AVARAGE 55 4 AUX SR R R DC 5 kW 56 54 54 57 6 UH75MF CENTRAL WOK L2 SINGLE BURNER EFFICIENCY AVARAGE 55 4 G20 G20 G25 1 G25 3 G30 G31 G30 G31 G30 G31 20 mbar 25 mbar 25 mbar 25 mbar 28 30 mbar 37 mbar 50 mbar Injector NG Injector NG Injector NG Injector NG Injector LPG Injector LPG Injector LPG Max Min Max Min Max Min Max Min Max Min Max Min Max Min ...

Page 24: ......