INSTALLATION IN FILTERING VERSION:
Prepare the power supply within the telescopic flue (for the electrical connection, follow all the other instructions
on the “Warnings” sheet).
Fixing to the wall
: for fixing to the wall refer to the instructions for the ducting version (see point 2, 3), then
continue with the instructions below.
Fixing the telescopic flues
: Using the supplied screws and screw anchors, fix the upper flue bearing bracket
to the ceiling and/or wall, checking that it is aligned with the hood (Fig. 7). Prepare the telescopic flues, remembering
that their final position must be that illustrated in Fig.12 (the air disposal gratings must be positioned in the upper part).
Take the air baffle and fit a flexible pipe to it (150 mm diameter) locking it with a metal hose clamp (pipe and clamps
are not provided). Fit the air baffle to the upper flue (Fig. 13) with 4 screws. Fix the telescopic flue to the bracket by
the screws provided (Fig.10A). Lift the lower flue upward and lock it temporarily with some adhesive tape: that way
you can access the flexible pipe which must be connected to the flange on the air evacuation pipe (Fig. 14). Make
the electrical connection. Remove the adhesive tape and bring down the lower flue gently and fix it by means of 4
screws working from the inside of the hood (Fig. 11).
Remember that charcoal filters must be used in the case of the filtering version; check to see whether such filters
are already fitted; if necessary, proceed to fit as follows, depending on the model type purchased:
- if the hood features a panel type charcoal filter (Fig. 15/16): Assemble the charcoal filter inserting the longer side
of the filter into the groove that runs parallel with the grease filter seat. Holding the filter on its side, insert the lock
supplied in its seat at the back (Fig. 15C) in order to avoid that it might be sucked onto the motor and bend it (Fig.
15A) so that its front side drives in (Fig. 15B). Fix the charcoal filter by means of the supplied locks (Fig. 16A), putting
them between the listel and the filter at the back of the seat of the filter. Keeping it blocked, make the lock rotate into
the back part until it embeds, minding that the charcoal filter does not get into the inside of the hood.
- if the hood features rectangular charcoal filter (Fig. 17): Install the charcoal filter fitting the two filter clips in their
housings and turning the filter upward.
Installation is now complete and the grease filters can be reassembled.
INSTALLATION IN VERSION WITH AN EXTERNAL MOTOR:
Before fixing the hood the air evacuation pipe running from the hood to the intaking motor should be ready . Use
an air evacuation pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend:
90°); – certified material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any
drastic changes in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all
the other instructions given on the “Warnings” sheet.
Prepare the power supply within the telescopic flue (for the electrical connection, follow all the other instructions
on the “Warnings” sheet).
For fixing to the wall refer to the instructions for the ducting version (see point 2, 3), then continue with the
instructions below.
Fixing the telescopic flues
: Using the supplied screws and screw anchors, fix the upper flue bearing bracket
to the ceiling and/or wall, checking that it is aligned with the hood (Fig. 7). Prepare the telescopic flues, remembering
that their final position must be that illustrated in Fig.8 (turn upside down the upper flue so that the air disposal gratings
are downwards). Connect the disposal duct to the air evacuation pipe of the hood. Use a flexible pipe and lock it to
the air evacuation pipe of the hood with a metal hose clamp - Fig. 9 (pipe and clamp are not provided).
Connect the hood to the external motor using the special terminal block (Fig. 18): remove wire clamp A and lid B from
the wiring junction box; fix the connecting wire of the external motor to terminal C; then replace wire clamp A and
lid B on the wiring junction box; the other end of the wire is secured to the terminal block on the external motor. Make
the electrical connection by means of the power cable.
Fix the telescopic flue to the bracket by the screws provided (Fig. 10A). Fix bottom side of the telescopic flue to the
hood by the screws provided. Screws must be worked from the inside of appliance (Fig. 11A).
Installation is now complete and the grease filters can be reassembled.
OPERATION
Depending on the model, the appliance is equipped with the following commands:
Commands shown in Fig. 19: Button A
= light button.
Button B
= first speed motor ON/OFF button.
Button C
= second speed button.
Button D
= third speed button.
E
= motor on light.
Commands shown in Fig. 20: Button A
: turns the lights on/off; every 30 hours of operation the corresponding pilot
lamp comes on to indicate that the grease filters must be cleaned; every 120 hours of operation the corresponding
pilot lamp flashes to indicate that the grease filters must be cleaned and the charcoal filters replaced. To restart the
hour counter (RESET), hold the button A pressed down for about 1” (while the pilot lamp is on).
Button B
: drives
the motor in first speed (the corresponding pilot lamp comes on); when holding it down for about 1”, the motor cuts
out; when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor
stops after 5’ (the pilot lamp flashes).
Button C
: drives the motor in second speed (the corresponding pilot lamp
comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus
the motor stops after 5’ (the pilot lamp flashes).
Button D
: drives the motor in third speed (the corresponding pilot
lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and
thus the motor stops after 5’ (the pilot lamp flashes).
Button E
: drives the motor in fourth speed (the corresponding
Summary of Contents for CMD 97 X
Page 20: ...1 2 A 3 4 ...
Page 21: ...5 6 A B B A C 7 8 9 ...
Page 22: ...10 A 11 A 12 13 14 ...
Page 23: ...15 C A B 16 A 18 19 20 21 A B C D E A B C D E A B C 17 ...
Page 24: ...04306663 2 K34el K34ce s n ...