background image

CONTENTS

CONTENTS

BRAND INTRODUCTION

BRAND INTRODUCTION

BRAND INTRODUCTION / 01

PRODUCTS / 02

CANDY Group — 

Candy is a European leading household appliances brand
that started in 1945 from the first washing machine to the latest
connected appliances. Since the launch of the first Italian
washing machine, Candy quickly became synonymous of
washing machine throughout Europe.

Today, Candy is one of the European leaders in household
appliances market, offering a comprehensive range of smart
practical, efficient, free standing & built-in appliances skillfully
combining the most advanced technologies with stylish
European design.

SAFETY NOTICES 

 

 SPECIFICATIONS & PACKING LIST

INSTALLATION INSTRUCTION

 INSTRUCTION MANUAL 

 TROUBLESHOOTING & INSTALLATION TEMPLATE  

02
03
04

06
07

P

01

P

01

 

 

 

SAFETY NOTICES

(Please read before use)

P

02

Attention

Warning

Prohibition

Instructions with this sign is prohibited,it may cause damage to the product or

 

 personal safety of the user.  

Instructions with this sign should be well attended by the user. Any misuse or ignorance 
may hurt or seriously injure the user.  

Instructions with this sign is related to safe use of the product an personal safety of the
 user. Operational rules should be strictly followed, or it may cause damage to the 
product or to personal safety of the user.  

230V/50Hz independent power source must be used at all times.

strictly prohibited.

Do not connect to power when installing or repairing the water heater.

Installation of water heater outdoors is strictly prohibited.

Do not use water from the water heater for drinking or similar purposes.

Please cut off the power supply if the water heater was not used for an 
extended period of time. Drain the water heater of all water according 

to the instructions in the chapter on Cleaning and Maintenance.

Do not install the water heater in an environment which is susceptible 

t

o ice-formation. Ice will cause the container and water pipe to break,

leading to scalding and water leakage.

Please take precautionary measures during cold weather, in order

 

to prevent damage to water heater from freezing.

If the soft power cable is damaged,it must be replaced by professional

st

aff from the manufacturers or Candy Service Center in order to 

avoid danger.

Take care not to be scalded by heater water.
    Touching of hot water valve and pipes is strictly prohibited.

    

Make sure to check the water temperature before use; use only 

    when it feels suitable.

Non-professionals are strictly prohibited from carrying out repairs,
maintenance, dismantling or revamping of the water heater.

Do not use damaged wire and p

ower socket. Promptly clean the dust 

on the power plug and socket.

C

heck the power meter and the electric wire’s diameter to ensure 

that they comply with the rated current for the water heater.Where

 

n

Do not touch the plug with wet hands, and make s

ure that the water

heater, plug socket do not come into

 contact with water. If they are

accidentally wet, they must be checked by 

professional persons

appointed by our company before using, in order to prevent

 

electrocution.

To ensure safety,the water heater should be connected to independent

sockets(do not use adapters),with reliable earthing. In addition the 
power socket must confirm to National Standards.use of water heater 

without reliable earthing is strictly prohibited. Use pen multimeter to 

check whether the live line and zero line are reverse. 

Immediately cut off power supply and contact Candy Service Centre 
once the water heater does not work properly or emits burnt smell.

MEANINGS OF ICONS

SAFETY NOTICES

BUILDING NO. – 1,OKHLA INDUSTRIAL

ESTATE, PHASE – 3,NEW DELHI - 110020

CANDY CARELINE

1800 202 9999

PACKING LIST

CM15LV

 

CM25LV

 

SPECIFICATIONS

ELECTRICAL DIAGRAM

P

03

TECHNICAL DATA

INTRODUCTION OF EXTERIOR AND ACCESSORIES

L : Live Wire (Brown/Red)
N : Neutral Wire (Blue/Black)
MT : High Temperature Limiter
BT : Thermostat
HL : Heating Indicator
EH : Heating Element
E : Earthing Wire (Yellow&Green)

Remarks: The permitted error limit of net weight above is±10%.

Front View       Side View     Cut View     Back View

Model        a              b           c              d            e

CM15LV   

 

         100mm

A:  Water Inlet Pipe
B:   Water Outlet Pipe
C:  Inner Container
D:  Heating Element
E:   Anode Rod
F:   Temperature
      Measurement Pipe
G:  Wall Mount Bracket
H:   Wall Rear Support  

Note:

         1.The margin of error for the above parameters(measurements,
            weight) is 

±

10%

             

             

 

Fig.3

INSTALLATION METHOD

Must be installed by personnel in Candy Service Person or

 

 designated installation personnel.

For ease of installation and removal of water heater,we would recommend that G1/2

 

loose joints be installed at appropriate locations on the water inlet pipes of the water
heater. Determine the position of the hot water supply. Connect the water inlet and 
outlet pipe together with the water pipe to the positions reserved for use of hot water.

 

Hot water pipe should preferably not be too long in order to prevent heat loss.

Determine the installation position of the water  heater.
Based on the measurements indicated in Fig. 2, use impact drill to drill two holes of  
12 mm in diameter and 65mm in depth. Insert the expandable hooks into the holes and 

 

onto the expandable hooks (as show in Fig.1).Check to make sure the machine is   

 

securely suspended. For accessories such as safety valve, please refer to the 
“Installation of Safety valve” (for reference only).Make sure to seal the joints with

Fig.1

Note: 

          Make sure that the water heater is securely attached to the hook before letting
          go; otherwise it may drop and cause injury or property damage.

The water heater is wall-mounted type.

INSTALLATION INSTRUCTION

P

04

DESCRIPTION OF PARTS

INSTALLING SAFETY VALVE

TEMP

MAX

Water

temperature

knob

Heating

indicator light

Cold water pipe

Safety valve

Cold water inlet

Direction of cold water

Direction of hot water

Hot water pipe

Sprinkler head

Install the safety valve which has a rated pressure of 
0.80±0.05MPa (its connection is G1/2) into the water 
inlet pipe with the arrow on the safety valve pointing
at the water heater. When the water heater is heated 
by electri

 

the safety valve’s pressure-relief hole due to the expansion 
of water in the heater. This is normal. The pressure-relief 
hole should be connected to the atmosphere and free 
from blockage at all times.

Small handle
for safety valve

Pressure-relief hole 

(connected to water 

drainage pipe)

Installation method for safety valve's drainage pipe: Attach an end of  
the water drainage pipe onto the pressure-relief hole on the safety valve. 
You may cut the water drainage pipe to make it shorter, or extend it 
depending on the situation.Connect to the other end of the water drainage 
pipe to the lower water outlet. This will prevent the water from the pressure 
relief hole from splashing. The water drainage pipe connected to the safety 
valve should be installed in a slanted manner and in an environment which 
is not prone to frost.
Note: If your water heater is not installed in a bathroom with sewer, our  

recommendation would be that you add safety valve water 

drainage pipe.
If Safety Valve is not installed, Product will not consider for

 

Warranty .

Silent Forest

CM25LV 368mm 405mm  581mm  152mm 

         100mm

335mm 371mm  466mm  152mm 

CM10LV   

         100mm

300mm 335mm  460mm  152mm 

CM10LV

 

2

                                    Unit            

  

       CM25LV

Mean Hot Water Output (Minimum)             

Re-heating Time(For temperature 

0

rise of 50 C)(Maximum)

Diameter Of Power Wire                                

                         3×1.0

0

C

Item  

CM15LV  

Rated Voltage    

V    

230    

230    

Rated Frequency

Hz    

50    

50    

Rated Pressure

Mpa    

0.80    

0.80    

Rated Power

W    

2000    

2000    

Net Weight

Kg    

11    

14    

Rated Capacity

L    

15    

25    

Waterproof Grade

IP   

IPX4    

IPX4    

Mixing Factor

%  

35    

35    

Tap Water Pressure (Minimum)

Mpa  

0.05    

0.05    

minutes

55    

55    

35    

55    

2

mm

          3×1.0  

  

                         3×1.0

CM10LV  

230    

50    

0.80    

2000    

8    

10    

IPX4    

35    

0.05    

55    

25    

Bring Home European Style

Summary of Contents for CM10LV

Page 1: ...User Manual WATER HEATER Please read this manual carefully before using water heater CM25LV CM15LV CM10LV Bring Home European Style ...

Page 2: ...ine Candy quickly became synonymous of washing machine throughout Europe Today Candy is one of the European leaders in household appliances market offering a comprehensive range of smart practical efficient free standing built in appliances skillfully combining the most advanced technologies with stylish European design SAFETY NOTICES SPECIFICATIONS PACKING LIST INSTALLATION INSTRUCTION INSTRUCTIO...

Page 3: ...er heater from freezing If the soft power cable is damaged it must be replaced by professional staff from the manufacturers or Candy Service Center in order to avoid danger Take care not to be scalded by heater water Touching of hot water valve and pipes is strictly prohibited Make sure to check the water temperature before use use only when it feels suitable Non professionals are strictly prohibi...

Page 4: ...Measurement Pipe G Wall Mount Bracket H Wall Rear Support Note 1 The margin of error for the above parameters measurements weight is 10 Fig 3 CM25LV 368mm 405mm 581mm 152mm 100mm 335mm 371mm 466mm 152mm CM10LV 100mm 300mm 335mm 460mm 152mm CM10LV 2 Unit CM25LV Mean Hot Water Output Minimum Re heating Time For temperature 0 rise of 50 C Maximum Diameter Of Power Wire 3 1 0 0 C Item CM15LV Rated Vol...

Page 5: ...LVE TEMP MAX Water temperature knob Heating indicator light Cold water pipe Safety valve Cold water inlet Direction of cold water Direction of hot water Hot water pipe Sprinkler head Install the safety valve which has a rated pressure of 0 80 0 05MPa its connection is G1 2 into the water inlet pipe with the arrow on the safety valve pointing at the water heater When the water heater is heated by e...

Page 6: ...e pipes should be closely laid out The hot water outlet should not be too far away from the point of usage If the distance exceeds 8 meters the hot water pipe should have insulation protection in order to prevent heat loss The wall on which the water heater should be strong such as it is able to withstand weight bearing wall or made of hollow bricks adequate protective measures such as addition of...

Page 7: ...ol or polish to clean the water heater Internal cleaning I and inner container should be cleaned once every two years Take care not to damage the exterior of the heating pipe or the protective layer on the surface of the inner container Depending on the local water quality and the usage habit the Anode rod might need to be regularly changed If maintenance is required please contact Candy Service P...

Page 8: ...age at customer s place Equipment creates abnormal Noise High voltage uctuations Hard water This is a normal phenomena and can be reduced by replacing the anode Equipment creates hissing Noise Due to scaling on Heating element Descale the Heating Element Unit not working Power point may not be working Need the electricity line at customer s place to be checked Check for any short circuit of harnes...

Page 9: ... not completed at the time of Purchase The complete warranty card is not presented to authorized service person at the time of service of the product The product is not operated according to Instruction given in user manual Defect or cause by improper reckless use which shall be determined by the authorized service person g Any repair work is carried out by the person other than authorized service...

Page 10: ...BUILDING NO 1 OKHLA INDUSTRIAL ESTATE PHASE 3 NEW DELHI 110020 CANDY CARELINE 1800 202 9999 ...