06 GB
WARNING: Manufacturer cannot be held responsible for any incident
or its consequences that may arise during the use of an appliance not
linked to the earth, or linked to an earth whose continuity is defective.
Before any electrical operation, please check the supply tension
shown on the electricity meter, the adjustment of the circuit- breaker,
the continuity of the connection to earth to the installation and that the
fuse is suitable.
The yellow/green wire of the power supply cable must be connected to
the earth of both power supply and appliance terminals.
To proceed to the new connection, please follow below instructions:
"Installation must conform to the standards & directives."
Before making the connection, make sure that the installation is
protected by a suitable fuse, and that it is fitted with wires of a large
enough section to supply the appliance normally.
Three Phase 380-415 V2N
Three Phase 220-240 V3
Manufacturer declines all responsibility for any damage that
might be caused by unsuitable or unreasonable use.
The electrical connection to the installation should be made according
to the rated power of the Appliance; this should be made via an Omni
pole cut-out switch.
It is however possible to connect the hob to:
For any questions regarding power supply cord refer to After Sales
Service or a qualified technician.
If the appliance has a socket outlet, it must be installed so that the
socket outlet is accessible.
If the hob is fitted with power supply cord, this shall be connected only
to a power supply of 220-240 V between phase and neutral.
2
3
1
Open the cover in the following sequence:
Turn over the hob, glass side against the working top, taking care to
protect the glass.
If it should be necessary to replace the power supply cord, connect the
wire in accordance with following colors/codes:
ATTENTION:
SHUNT
- put the blade of a flat screw-driver in front of each tab "2" e
"3", push in and press;
To release the power supply cord:
- unscrew the cable clamp "1";
- find the two tabs located on the sides;
- remove the cover.
- Remove the screws retaining the terminal block which
contains the shunt bars and the conductors of the supply cord;
Operations to be carried out to make a new connection:
- Choose the power supply cable in accordance with the
- Pull out the supply cord.
Note: make sure the terminal board screws are tight.
recommendations in the table;
- Pass the power supply cable into the
clamp;
- Strip the end of each conductor of the
supply cord on a 10 mm length, by taking in
account the requested length of the cord for
the connection to the terminal block;
- According to the installation and with the
help of shunt bars which you should have
recovered in the first operation, fix the
conductor as shown on the chart;
- Fix the cover;
- Screw the cable clamp.
Connection to the terminals on the terminal block
LAY OUT
"1-6"
LAY OUT
"7"
MONOPHASE or TWO PHASES 220-240 V
~
Cable
HO5V2V2F
Cable
HO5V2V2F
Cable
HO5V2V2F
2
3x2,5 mm
2
3x4 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
THREE PHASES 220-240 V
3~
THREE PHASES 380-415 V
2N~
N
=
Neutr
al
PE
=
Earth
L1 / L2 / L3 =
Phase
220-240V 3 ~
PE
L1
L2
L3
380-415V 2N ~
N
PE
L1
L2
L3
PE
L1
L2
220-240V ~
N
L
220-240V 2 ~
L2
PE
L1
PE