COUPLING OF THE BUILT-IN COLUMN
PANELS TO THE DOORS OF THE APPLIANCE
The appliance is equipped with coupling devices for the appliance
doors with the column panels (drive sleds).
Fasten the sled in the inner part of the built-in column panel at the
desired height and at approx. 20 mm from the outer wire of the door.
PRECAUTIONS FOR THE CORRECT
FUNCTIONING
Once the product has been built in, position the rear part of the column
in contact with the wall so as to prevent access to the compressor
compartment.
For the product to operate correctly it is essential to allow adequate air
circulation so as to cool down the condenser located in the rear part of
the appliance.
For this reason, the column must be equipped with a rear chimney,
whose upper opening must not be blocked and with a front slot which
will be covered with a ventilation grill.
Dimensions of the column lock-pickings.
Dimensions of the gap to be left between the column and the ceiling.
Connect the appliance door to the cabinet panel having the sled slots
as references.
Mark the fi xing points for the screws and drill with a bit of a diameter
of 2.5.
Open the doors of the built-in column and the fridge. Position the built-
in loader in the slide, then fi t it into the fridge door.
50 mm
380 mm
540 mm
50
mm
50
mm
9 EN