2
6
4.
Put wiring cover back and then tighten the screw.
5.
Close the panel.
Installation of indoor unit
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
● If the length of power connection wire is insufficient, please contact the supplier
for a new one. Avoid extending the wire by yourself.
● For the air conditioner with plug, the plug should be reachable after finishing
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
and then fix the power connection wire
with wire clip.
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
07
、
09
、
12K Heat pump type:
violet
black
yellow-
green
orange
blue
outdoor unit connection