- 23 -
A(V)N(P)120
’
s Protocol Version 1.1
Æ
00 hex ~ FF hex : AGC control level data
x
RR
*NN8BXXXXYY
*RR000000YY
Read
AGC Level
Æ
Negative mode ON
Æ
Negative mode OFF
00
01
PP
*NN8CPPXXYY
Set
Negative On/Off
Æ
Inner area weight data
Æ
Outer area weight data
R
S
*NN8EXXXXYY
*RS000000YY
Read Iris Area
Weighting value
Æ
00 ~ 27 : Shutter counter
00 : 1/60 01 : 1/125 04 : 1/250 09 : 1/500
14 : 1/1000 21 : 1/2000 25 : 1/4000
27 : 1/10000
x
RR
*NN85XXXXYY
*RR000000YY
Read
Shutter Speed
Counter
Æ
00 ~ FF : Backlight level
x
PP
*NN84PPXXYY
Adjust
Backlight Level
Æ
00 hex ~ FF hex : AGC level data
x
PP
*NN87PPXXYY
Set
AGC Level
Æ
00 ~ 27 : Shutter counter
x
PP
*NN86PPXXYY
Set
Shutter Speed
Æ
00 hex ~ FF hex : Iris control level data
x
RR
*NN89XXXXYY
*RR000000YY
Read
Iris Level
Æ
00 hex ~ 60 hex : Brightness level data
x
RR
*NN88XXXXYY
*RR000000YY
Read
Brightness Level
Set the Iris Open Level
Æ
00 hex ~ FF hex : Iris control level data
x
PP
*NN8APPXXYY
Set
Iris Level
x
00
01
Æ
00 ~ FF : Backlight level
RR
*NN83XXXXYY
*RR000000YY
Read
Backlight Level
Æ
Backlight mode OFF
Æ
Backlight mode ON
PP
*NN82PPXXYY
Set
Backlight Mode
Contents
Command
Option
Command Packet
Command
Message
Camera Status Control Commands - 2