- 17 -
A(V)N(P)120
’
s Protocol Version 1.1
Æ
Sensitivity level of Slow shutter
Level Range : 00 ~ 1F
00 ~
1F
PP
*NN9BPPXXYY
Set the
Sensitivity level
of Slow shutter
Æ
Sensitivity level of Slow shutter
Level Range : 00 ~ 1F
00 ~
1F
RR
*NN9AXXXXYY
*RR000000YY
Read the
Sensitivity level
of Slow shutter
Æ
Slow shutter max field index(00~09)
Index
: 00 01 02 03 04 05 06 07 08 09
Max Field : 00 02 04 08 12 16 24 32 64 128
00~
09
PP
*NN9CPPXXYY
Set the Slow
shutter max field
Change Day&Night mode
…
Æ
OFF
Æ
AUTO
Æ
ON
Æ
OFF
Æ
….
-
-
*NN9DXXXXYY
Change
Day&Night
mode
Execute Lens Initial action. After this action, the
zoom and focus lenses will be moved to the working
position. And continue the previous working.
If this lens initial action is finished, then the
Command Response Packet will be transmitted.
-
-
*NNADXXXXYY
Lens Initial
01
00
01
00
Æ
Reverse the picture (rotate 180 degrees)
Æ
Normal state (release the reverse state)
(!!)AN(P)122F model only
PP
*NNAFPPXXYY
Reverse/Normal
Æ
Freeze the picture
Æ
Live (release the freeze state)
(!!) AN(P)122F,AN(P)120L model only
PP
*NNAEPPXXYY
Freeze/Live
Contents
Command
Option
Command Packet
Command
Message
General Control Commands - 2