13
Programming Instructions
1. Press SETTINGS to enter programming. If the system has been inactive, you may
have to hold and press SETTINGS to unlock the display screen. Press UP or DOWN to
select which setting to modify.
2. To adjust a value, press SELECT. When the display flashes, the value may be
changed. Press UP or DOWN to change the value. Press SELECT again to accept the
value.
3. Press UP or DOWN to advance to the next option.
4. At any time, press SETTINGS to return to previous home screen menu.
The table below can be used to help deter-
mine the frequency of regeneration for Multi-
Media and Taste & Odour filters. Use this ta-
ble as a guide since individual circumstances
will require more or less frequent regenera-
tions. This can be adjusted by the home
owner to suite their individual needs with fre-
quencies available from 1 – 99 days.
To prevent bacterial build up in the media,
activated carbon filters should not exceed 6
days between backwashes.
Sediment
Mild
Average
Extreme
Taste Odor
Mild
Average
Extreme
No. Of Per-
sons
Days Between Back Wash (Regenerations)
2
6
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
6
6
6
6
4
4
4
4
4
4
3
3
3
3
3
3
4
6
6
6
6
4
4
4
3
3
3
2
2
2
2
2
2
5
6
6
4
4
3
3
3
3
2
2
2
2
1
1
1
1
6
6
6
4
4
3
3
3
2
2
2
2
1
1
1
1
1
7
6
4
4
3
3
2
2
2
1
1
1
1
1
1
1
1
8
6
4
4
3
2
2
2
2
1
1
1
1
1
1
1
1
9
4
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
10
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
Backwash Frequency
Summary of Contents for 765 Series
Page 11: ...11 Filter Installation ...
Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors ...
Page 19: ...19 Control Valve Exploded View ...
Page 20: ...20 Control Valve Parts List ...
Page 21: ...21 Power Head Exploded View ...
Page 22: ...22 Power Head Parts List ...
Page 23: ...23 Trouble Shooting ...