Canature WaterGroup Tannins 89 TLC Owner'S Manual Download Page 6

6  

1. If your hot water tank is electric, turn off the power to it to avoid damage to the element 

in the tank. 

2. If you have a private well, turn the power off to the pump and then shut off the main wa-

ter shut off valve.  If you have municipal water, simply shut off the main valve.  Go to the 
faucet, (preferably on the lowest floor of the house) turn on the cold water until all pres-
sure is relieved and the flow of water stops. 

3. Locate  the  softener  tank  and  brine  tank  close  to  a  drain  where  the  system  will  be  in-

stalled.  The surface should be clean and level. 

4. Connect the inlet and outlet of the softener using appropriate fittings.  Perform all plumb-

ing according to local plumbing codes. 

• 

Use a ½” minimum pipe or tubing size for the drain line 

• 

ON  COPPER  PLUMBING  SYSTEMS  BE  SURE  TO  INSTALL  A  GROUNDING 
WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUND-
ING.

 

Any  solder  joints  near  the  valve  must  be  done  before  connecting  any  piping  to  the  valve.  
Always leave at least 6" (152 mm) between the valve and joints when soldering pipes that 
are connected to the valve.  Failure to do this could cause damage to the valve. 
 
5. Connect the drain hose (10 ft included) to the valve and secure it with a hose clamp (also 

included).  Run the drain hose to the nearest laundry tub or drain pipe.  This can be ran 
up overhead or down along the floor.  If running the drain line more than 20 ft overhead, 
it is recommended to increase the hose size to 3/4”.  NEVER MAKE A DIRECT CONNEC-
TION INTO A WASTE DRAIN.  A PHYSICAL AIR GAP OF AT LEAST 1.5” SHOULD BE USED 
TO  AVOID  BACTERIA  AND  WASTEWATER  TRAVELLING  BACK  THROUGH  THE  DRAIN 
LINE INTO THE SOFTENER. 

6. Using the Allen Key (included), place the unit in the bypass position.  Slowly turn on the 

main  water  supply.    At  the  nearest  cold  treated  water  tap  nearby  remove  the  faucet 
screen, open the faucet and let water run a few minutes or until the system is free of any 
air or foreign material resulting from the plumbing work. 

7. Make sure there are no leaks in the plumbing system before proceeding.  Close the water 

tap when water runs clean. 

8. Open  the  brine  tank  /  cabinet  salt  lid  and  add  water  until  there  is  approximately  3"  (75 

mm) of water in the  tank.  Do not add salt to the brine tank at this time. 

9. Proceed to start up instructions. 

Note:    The  unit  is  not  ready  for  service  until  you complete  the  start-up  instruc-
tions. 

Installation Instructions 

Summary of Contents for Tannins 89 TLC

Page 1: ...ith install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or aft...

Page 2: ...treating water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Page 3: ...ces Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nigh...

Page 4: ...rate may affect capacity and efficiency performance The manufacturer reserves the right to make product improvements which may deviate from the specifications and descriptions stated herein without ob...

Page 5: ...not covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Page 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Page 7: ...7 Installation...

Page 8: ...e O ring is coated with grease 2 Connection method of inlet and outlet connector same as the above make sure to connect according to the direction of arrow seeing from the top view 3 It is also recomm...

Page 9: ...en close the bypass valve slowly open the inlet valve the raw water filling the tank and empty the air of the system open the valve more until the backwash water is clean 5 Press any key to advance th...

Page 10: ...s the Flow Rate Date Time Of Day Remaining Volume and Total Volume The display will alternate between the main page and the dealer information page PROGRAM LEVEL USER ACCESS MAIN MENU II These setting...

Page 11: ...E Time of day is for normal operation of system and the scheduling of the regeneration time The date is used in a diagnostic function to track the last time the sys tem regenerated HARDNESS This value...

Page 12: ...FLOW valve backwash brine slow rinse fast rinse service refill The regeneration steps of UP FLOW valve brine slow rinse backwash fast rinse service refill Set the Down Flow valve as an example when th...

Page 13: ...Rinse the screen will display Press any key will stop fast rinse and the valve will advance to the next regeneration process Refill the screen will display Press any key will stop service refill and t...

Page 14: ...ear 1 8 Connect screw 1 9 85HE main gear 1 10 Brine gear screw 1 11 Locating wheel assembly three options Down flow wheel Up flow wheel Filter wheel 1 12 85HE brine gear 1 13 Micro switch screws 2 14...

Page 15: ...No Part description Qty No Part description Qty 1 Big O ring of Adaptor coupling 2 6 89 secure clip 2 2 Adaptor coupling of 89 control valve 2 7 89 valve connector 1 3 Small O ring of adaptor coupling...

Page 16: ...assembly optional 1S 2S 3S 4S 1 3 4 5 6 1 4 Drain elbow O ring 1 5 Drain elbow 1 2 3 4 1 6 Brine valve injector stem assembly 1 7 Spacer and seal assembly 1 8 Three options of piston Down flow piston...

Page 17: ...rine line adaptor assem bly optional BLFC 0 7gpm BLFC 0 95gpm 1 16 Injector assembly optional grey purple red white blue yellow 1 17 Injector cover O ring 1 18 Injector cover 1 19 Injector cover screw...

Page 18: ...ia to form or grow However during shipping storage installing and operating bacteria could get into the softener For this reason sanitizing as follows is suggested when installing Sani System Liquid S...

Page 19: ...ions described in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation...

Page 20: ...20...

Reviews: