Canature WaterGroup AQUA FLO AQUV-12R22 Owner'S Manual Download Page 11

10

11

Aqua Flo logo & lamp part #

Blue ends

(G) OPERATION AND MAINTENANCE

Your UV system is ON continuously during normal use and will continuously supply safe water. (Note: Do not try to shut it off during short periods of 

non-use as repeated ON/OFF cycles can shorten the UV lamp and ballast life).  Failure to follow disinfection procedure if the system is shut off could 

result in micro-biologically unsafe water leading to potential illness or death.

To maintain the optimum disinfection performance of the UV system: 

—

  UV lamp should be replaced when the display reaches “0”. At this point, the UV lamp continues to light but its ability to disinfect the water drops  

  below safe limits. Therefore the 

UV lamp MUST BE REPLACED WHEN THE LAMP REPLACEMENT ALARM “A3” COMES ON

.

—

  The quartz dome should be cleaned at the time of lamp replacement. If the water quality parameters listed in section ‘C’ are exceeded, you  

  should clean and inspect the quartz dome more frequently and clean as necessary.

—

  Replace pre-filters every 4-6 months. 

CHANGING FILTER CARTRIDGES & REPLACING O-RINGS:

1.

   Shut off the inlet valve and open a faucet close by until pressure in the unit is relieved. Alternatively you can press the red vent button on top of   

 

the unit until pressure is released.

2.

   Place an empty bucket under the sump to catch any water spilling out of the housings.

3.

   Using the supplied wrench, unscrew the sump. Discard old cartridge and rinse sump.

4.

   Remove O-rings and replace if they have been in use for a year. Otherwise wipe them with a soft cloth or paper towel and clean the groove on   

 

which the O-rings are seated.

5.

   Apply food-grade silicone lube on the O-rings and replace.

6.

   Clean inside of the head as well to make sure the sealing surface is free of debris and stains.

7.

   Insert new cartridge into the sump and screw sump back on to filter. Hand-tighten    

 

only.  Slowly open the water and flush for a few minutes before use. 

WARNING

USE ONLY GENUINE AQUA FLO AQUV  LAMPS

Use only GENUINE AQUA FLO AQUV  UV Lamps with your UV system. Aqua Flo UV lamps are designed 

with extensive product research and engineering to provide reliable and consistent UV output and 

performance that ensures the safety of your drinking water. Using non-Aqua Flo AQUV  UV lamps can 

not only compromise the system performance but also voids your product warranty, electrical and CSA 

certification, and may result in any one or more of the following issues:

 

 Unsafe drinking water which may lead to illness and/or death 

 Ballast failure  

 Electrical fire

Use of non-Aqua Flo AQUV  lamps will void all warranty & product certification

Genuine Aqua Flo AQUV  lamps can be identified as follows:

CAUTION!

DO NOT USE WRENCH TO TIGHTEN SUMP.

ITEM

REPLACEMENT FREQUENCY

CLEANING

UV Lamp

Every 1 year of use

N/A

Quartz Dome

Every 3 years

At least during every annual lamp change. More 

frequently if water is hard or has iron, manganese etc.

O-Rings

Annually

N/A

Sediment 

Pre-Filter

6 months or when pressure across 

the unit drops by 10psi

N/A

Summary of Contents for AQUA FLO AQUV-12R22

Page 1: ...installed in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure to install the system correctly voids the warranty 6 Handle all components of the system with care Do not drop drag or turn components upside down 7 Save these instructions and keep track of your prod...

Page 2: ......

Page 3: ...organisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy A INTRODUCTION 4 B SAFETY GUIDELINES 4 C WATER QUALITY REQUIREMENTS 5 D INSTALLATION 6 E DISINFECTION PROCEDURE 10 F BALLAST FOR AQUV UV SYSTEMS 10 G OPERATION AND MAINTENANCE 11 H TROUBLESHOOTING 12 I TECHNICAL SPECIFICATIONS 13 J PARTS LIST 13 K WARRANTY 16 Teste...

Page 4: ...y safe technique that is not known to form any harmful disinfection by products Fig 1 B SAFETY GUIDELINES Lamp contains mercury Hg Dispose or recycle in accordance with applicable laws For information on safe handling procedures and safe disposal and recycling consult Contains mercury Hg Diverting Mercury Management of Lamps Containing Mercury Indicates a hazardous situation which if not avoided w...

Page 5: ...UV LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV lamps can result in unsafe drinking water which may lead to illness and or death ballast failure or fire and will void your product warranty see page 12 for details Canature WaterGroup U S A Inc Cana...

Page 6: ...he AQUV 20 AQUV 12 systems have been designed for maximum water flow rates of 20 US GPM 70 liters per minute and 12 US GPM 45 liters per minute respectively If higher flow rates exist occasionally it is recommended that a flow restricter be installed at the inlet port 12 US GPM for AQUV 20 and 12 US GPM for AQUV 12 The system should be installed indoors in a protected area where the temperature do...

Page 7: ...pipes divide into hot and cold Fig 2 Water Meter OR UV System Water Heater Cold water to house Hot water to house CityWater WellWater Water Softener Optional PressureTank WellWater Water Flow OR Water Flow Water Flow Water Flow Fig 2 Fig 3 Fittings Required for Installation Not Included Fittings required for a typical install on 3 4 copper pipe are 3 4 FNPT female adapters 3 4 Tee 3 4 Elbows 3 4 c...

Page 8: ... the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dome The thinner o ring is installed in the groove of the gland nut 5 Gently slide the dome O ring thicker over the top open end of the quartz dome to about 1 from the open end Fig 4 6 Gently insert the...

Page 9: ... the plastic making it easy to hook up lamp then white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the ground wire green wire with yellow stripes over the stud and tighten the nut 12 Connect the ballast power cable to the AC supply with surge protector The green lamp on LED will light up and the display will...

Page 10: ...y and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV ballast is for use with Aqua Flo AQUV 8 AQUV12 AQUV 20 Systems It features both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer NOR...

Page 11: ...ard old cartridge and rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade silicone lube on the O rings and replace 6 Clean inside of the head as well to make sure the sealing surface is free of debris and stains 7 Insert new cartridge into the sump an...

Page 12: ...econd beep This will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter by removing the sump and dump the wate then drain the UV chamber of all water Let the filter cartridge dry out and then reinstall in the housing To drain the UV undo the SS flex connect...

Page 13: ...mber Mounting SS Nut 1 8 36003038 Quartz Dome for AQUV 12 1 9 36003039 Quartz Dome for AQUV 20 1 10 80127302 Dome O Ring Thicker 1 2 for AQUV 20 11 80127301 Gland Nut O Ring Thinner inside nut 1 2 for AQUV 20 12 89113 UV Lamp for AQUV 12 1 13 89114 UV Lamp for AQUV 20 1 14 80127402 Lamp Spring 1 15 36112 Pre filter head 2 20 Sump for pre filter 2 Pressure vent button 2 BH Mounting screw 8 BH mount...

Page 14: ......

Page 15: ......

Page 16: ...uding any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 This warranty will not apply if water passing thr...

Reviews: