Canature WaterGroup AQUA FLO AQUV-12R22 Owner'S Manual Download Page 10

10

BUTTON

 

RED LED

 

GREEN LED

 

DISPLAY

 

(E) DISINFECTION PROCEDURE

Before service begins, all household plumbing lines should be disinfected to prevent the possibility of re-contamination after UV disinfection. You 

should also disinfect your plumbing system if the power goes out for several hours or more or if the unit has been accidentally shut-off for several 

hours or more. It is advisable to disinfect the plumbing lines at least once a year. If the bypass is used, the water system of the house should be 

disinfected in the same way it was in initial installation. Disinfect after using bypass as well. 

The following is a general method for disinfection of plumbing lines. If you are uncertain about the 

efficacy of this procedure you are advised to contact your local health authority responsible for water 

safety.

1.

  Shut off the supply valve and de-pressurize the lines by opening a tap until it runs dry.

2.

  Remove the filter in the filter housing and add about 1-2 cups (250-500ml) of unscented household bleach (5 to 6% sodium hypochlorite) to the  

  empty filter housing and put it back on the filter head.

3.

  Open the supply valve and slowly open a faucet and let the water run until you can smell the chlorine and then shut the faucet off. Repeat the  

  procedure for all hot and cold outlets in the house. Add more bleach as required. Run hot faucets longer to allow the chlorine to come through  

  the hot water tank.

4.

 Leave the bleach solution in the plumbing system for about 6 to 8 hours preferably overnight.

5.

  Shut-off the supply valve again and open a faucet to depressurize the system. Open the filter housing and re-install the filter cartridge and then  

  re-attach the filter housing. Make sure that the UV system is ON.

6.

 Take off aerators (if any) on the faucets, open the supply valve slowly, and  

  thoroughly flush all outlets until the chlorine smell is minimal.

7.

 You are ready to use the water now.

(F) BALLAST FOR AQUV UV SYSTEMS

Aqua Flo AQUV advanced micro-processor controlled electronic UV ballast is for use with Aqua Flo AQUV-8,  AQUV12 & AQUV-20 Systems. It features 

both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer.

 

NORMAL DISPLAY:

 Number of days left before lamp expires and must be   

   

replaced. Starts at 365 and ends at 0.

 

Press button to display the total running days of the unit since installation   

   

(maximum 9999 days). Display goes back to default after 10 seconds.

 

“LF”

 - LAMP FAULT: If the lamp is disconnected or defective (burned out), the  

   

display will show "LF" with the red LED on, and the ballast will beep every 2 secondss. If you press the button once, display will show  

   

“lamp life remaining” and go back to “LF” after 10 seconds. If you press the button again before 10 seconds, display will show “total  

   

running time” and then after 10 seconds go back to “LF”. In the “LF” alarm do not consume water until you replace UV lamp and  

   

cleared the alarm.

“A3”

 – LAMP EXPIRY: If the display shows “A3” alarm with red LED on and ballast beeps every 5 seconds, it indicates that the lamp has  

   

expired. Do not consume water until lamp is replaced.

You can silence the alarm for 7 days by pressing and holding the button until 

“dELy” 

is displayed. You can silence the alarm 3 times  

   

after which the alarm will not silence until you replace the UV lamp.

RESETTING THE LAMP EXPIRY TIMER:

 After replacing the UV lamp annually, you must re-set the ballast timer to clear the “A3”  

   

alarm. To do this press and hold the button for approx 10 seconds until 

“rSET”

 is displayed. Release button and the ballast will emit a  

   

long beep to confirm reset. Green LED will come on and red LED will turn OFF. Display will show “365” again.

WARNING

Failure to follow disinfection procedure could result in  

micro-biologically unsafe water leading to potential 

illness or death.

Summary of Contents for AQUA FLO AQUV-12R22

Page 1: ...installed in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure to install the system correctly voids the warranty 6 Handle all components of the system with care Do not drop drag or turn components upside down 7 Save these instructions and keep track of your prod...

Page 2: ......

Page 3: ...organisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy A INTRODUCTION 4 B SAFETY GUIDELINES 4 C WATER QUALITY REQUIREMENTS 5 D INSTALLATION 6 E DISINFECTION PROCEDURE 10 F BALLAST FOR AQUV UV SYSTEMS 10 G OPERATION AND MAINTENANCE 11 H TROUBLESHOOTING 12 I TECHNICAL SPECIFICATIONS 13 J PARTS LIST 13 K WARRANTY 16 Teste...

Page 4: ...y safe technique that is not known to form any harmful disinfection by products Fig 1 B SAFETY GUIDELINES Lamp contains mercury Hg Dispose or recycle in accordance with applicable laws For information on safe handling procedures and safe disposal and recycling consult Contains mercury Hg Diverting Mercury Management of Lamps Containing Mercury Indicates a hazardous situation which if not avoided w...

Page 5: ...UV LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV lamps can result in unsafe drinking water which may lead to illness and or death ballast failure or fire and will void your product warranty see page 12 for details Canature WaterGroup U S A Inc Cana...

Page 6: ...he AQUV 20 AQUV 12 systems have been designed for maximum water flow rates of 20 US GPM 70 liters per minute and 12 US GPM 45 liters per minute respectively If higher flow rates exist occasionally it is recommended that a flow restricter be installed at the inlet port 12 US GPM for AQUV 20 and 12 US GPM for AQUV 12 The system should be installed indoors in a protected area where the temperature do...

Page 7: ...pipes divide into hot and cold Fig 2 Water Meter OR UV System Water Heater Cold water to house Hot water to house CityWater WellWater Water Softener Optional PressureTank WellWater Water Flow OR Water Flow Water Flow Water Flow Fig 2 Fig 3 Fittings Required for Installation Not Included Fittings required for a typical install on 3 4 copper pipe are 3 4 FNPT female adapters 3 4 Tee 3 4 Elbows 3 4 c...

Page 8: ... the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dome The thinner o ring is installed in the groove of the gland nut 5 Gently slide the dome O ring thicker over the top open end of the quartz dome to about 1 from the open end Fig 4 6 Gently insert the...

Page 9: ... the plastic making it easy to hook up lamp then white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the ground wire green wire with yellow stripes over the stud and tighten the nut 12 Connect the ballast power cable to the AC supply with surge protector The green lamp on LED will light up and the display will...

Page 10: ...y and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV ballast is for use with Aqua Flo AQUV 8 AQUV12 AQUV 20 Systems It features both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer NOR...

Page 11: ...ard old cartridge and rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade silicone lube on the O rings and replace 6 Clean inside of the head as well to make sure the sealing surface is free of debris and stains 7 Insert new cartridge into the sump an...

Page 12: ...econd beep This will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter by removing the sump and dump the wate then drain the UV chamber of all water Let the filter cartridge dry out and then reinstall in the housing To drain the UV undo the SS flex connect...

Page 13: ...mber Mounting SS Nut 1 8 36003038 Quartz Dome for AQUV 12 1 9 36003039 Quartz Dome for AQUV 20 1 10 80127302 Dome O Ring Thicker 1 2 for AQUV 20 11 80127301 Gland Nut O Ring Thinner inside nut 1 2 for AQUV 20 12 89113 UV Lamp for AQUV 12 1 13 89114 UV Lamp for AQUV 20 1 14 80127402 Lamp Spring 1 15 36112 Pre filter head 2 20 Sump for pre filter 2 Pressure vent button 2 BH Mounting screw 8 BH mount...

Page 14: ......

Page 15: ......

Page 16: ...uding any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 This warranty will not apply if water passing thr...

Reviews: