16
17
Fig. 2.
Brine tube
stiffener
MANUAL WATER BYPASS
I
n case of an emergency, or to perform softener maintenance, you can
isolate your water softener from the water supply using the bypass valve
located at the back of the control.
In normal operation the bypass is OPEN with the ON/OFF knobs in line
with the INLET and OUTLET pipes, i.e., the black marks in the vertical
position. See SERVICE below.
To isolate the softener, simply rotate the knobs as indicated to the CLOSE
position until they lock. You can continue to use your water related
fixtures as the water supply is bypassing the softener. However, the
water you use will be untreated.
To resume treated service, OPEN the bypass valve by rotating the knobs
back to the SERVICE position.
NOTE
Please make sure bypass knobs are completely open
otherwise the untreated water may enter
through the valve.
OPEN
OPEN
CLOSE
OPEN
OPEN
CLOSE
OPEN
OPEN
CLOSE
SERVICE
INLET
OUTLET
INLET
OUTLET
BYPASS
INSTALLATION STEPS
(CONTINUED)
7.
Attach the brine line from brine tank to brine line fitting on control valve. install the tube
stiffener into the end of the brine line before attaching it to the brine line fitting on the
control valve See
Fig. 2
.
8.
Using the included Allen key, place the unit in the bypass position.
a.
Slowly turn the main water supply ON.
b.
At the nearest cold treated water tap, remove the tap screen, OPEN the tap and let
water run a few minutes or until the system is free of any air or foreign material
resulting from the plumbing work.
9.
Make sure there are no leaks in the plumbing system before proceeding. Shut the water tap OFF when the water runs clean.
NOTE
If the tap has a screen, it should be removed to
allow debris to flush out of the plumbing.
Summary of Contents for 85UF