background image

PLF SERIES

 

 

WALL EXHAUST FAN

M0017_PLF SERIES_02_21_2023

Page 2 of 5

GENERAL INFORMATION

This fan is made of materials that ensure long lasting performance and is designed with features that make it one of the most efficient and 
easy to use and care for fans available today. 
 
Your fan comes completely assembled except for the metal turn clips that can be quickly assembled into the pre-drilled holes around the 
outside flanges of the fan. All fans are tested for proper operation before leaving the factory. Your fan should be installed into a wood 
frame.

 See Chart #1

 for dimensions. 

Model

H

W

PLF12

15"

15"

PLF14

17.25"

17.25"

PLF16

19.25"

19.25"

PLF18

21.25"

21.25"

PLF20

23.25"

23.25"

PLF24

27.25"

27.25"

PLF36

40.25"

40.25"

Rough Inside Opening Frame Dimension

CHART #1

PLF12 to PLF24 Models

 

Simply remove the fan from the carton and proceed to next section. 

 
PLF36 Models

 

Remove the fan from the shipping pallet by removing the 6 screws holding the fan to the pallet. A hardware bag is secured to the motor 
support arm. The hardware bag contains 8 turn clips, 8 nylon washers, 8 10-24 x 3/4" stainless steel screws, and 8 nylon insert nuts. This 
hardware is for the turn clips that hold the shutter assembly in place. 
 
Assemble the 8 turn clips to the pre-drilled holes. There are 3 holes down each side flange and 1 on each of the top and bottom flanges. For 
each of the 8 turn clips insert the screw through the hole from the back of the flange, slide on a nylon washer, then the clip, and thread the 
nut. Tighten the turn clips with a Phillips screw driver and a 3/8" socket wrench. 

(see Figure 1-b).

 

 

All Fan Models

 

With the shutter removed, slide the fan into the framed opening. Push the fan up against the top of the frame to be sure the fan slopes 
downward for drainage to the outside. Secure the 4 corners with lag bolts. Secure the 4 sides, being sure the inside dimensions of the fan 
are consistent between flanges so that clips and shutters will operate correctly 

(see Figure 1-a).

 

This will also ensure that the orifice is not 

deformed, which may cause the blade to hit the tunnel of the fan. 

 

CAUTION: If using expanding foam to insulate, make sure expansion pressure does not damage the housing.

INSTALLATION

Inside View of Fan - Be Sure All Similar Dimensions Are Equal When Mounting Fan

Figure 1-a

Figure 1-b

Summary of Contents for PLF Series

Page 1: ...ns INSTALLATION OR PRODUCT PROBLEMS DO NOT RETURN TO STORE OF PURCHASE CONTACT CANARM SERVICE AT 1 800 265 1833 CANADA 1 800 267 4427 U S A 1 800 567 2513 EN FRAN AIS MONDAY TO FRIDAY 8 00 5 00PM E S...

Page 2: ...ips 8 nylon washers 8 10 24 x 3 4 stainless steel screws and 8 nylon insert nuts This hardware is for the turn clips that hold the shutter assembly in place Assemble the 8 turn clips to the pre drille...

Page 3: ...to the motor On some models there are holes punched along the lengths of the arms It is recommended that you use cable ties provided in hardware bag to attach cable to arm see Figure 2 Make sure the c...

Page 4: ...p should occur on blade motor guard and louvers for proper fan operation and to prevent premature failure The complete fan should be washed down on a regular basis to maintain the high efficiency of t...

Page 5: ...ng or tightening Tightening can be done by moving the screw location on the tensioner bracket see figure 4 Although we recommend replacing the belt Lubrication Belt drive fans are provided with bearin...

Page 6: ...A CLIENT LE CHEZ CANARM AU 1 800 265 1833 CANADA 1 800 267 4427 USA 1 800 567 2513 EN FRAN AIS DU LUNDI AU VENDREDI ENTRE 8 00H ET 17 00H HNE PRECAUTIONS G N RALES Les pi ces rotatives poulies arbre e...

Page 7: ...au bras de support du moteur Le sac contient 8 attaches tournantes 8 rondelles de nylon 8 vis en acier inoxydable 10 24 x et 8 crous d insert en nylon Ce mat riel est destin aux attaches tournantes q...

Page 8: ...TILATEUR D EXTRACTION MURAL M0017_PLF SERIES_FR_02_21_2023 Page 3 de 5 CONNEXIONS LECTRIQUES MISE EN GARDE TOUS LES TRAVAUX LECTRIQUES DEVRONT TRE EX CUT S PAR UN LECTRICIEN QUALIFI MISE EN GARDE FERM...

Page 9: ...t et arri re et des protections avant pour une meilleure performance dans le d placement de l air Le moteur doit tre maintenu propre pour viter une surchauffe et une panne pr matur e Comme pour tous l...

Page 10: ...d Si ge Social 2157 Parkedale Avenue PO Box 367 Brockville Ontario Canada K6V 5V6 Tel 613 342 5424 Fax 613 342 8437 MISE EN GARDE LES MOTEURS SONT QUIP S D UNE PROTECTION AUTOMATIQUE CONTRE LES SURCHA...

Reviews: