LOCATING AND MOUNTING THE WATERER

  (

TOP VIEW OF WATERER INSTALLED ON FENCE LINE)

   

                                                              

                                                          

  READ AND SAVE THESE INSTRUCTIONS

MODELS:   HL50-09, H50-09, H100-09,  H200, P25, P50 and P100

General Information:  

Canarm’s Energy Efficient Heated Livestock Waterers are designed for both durability and ease of use.  Our H50/HL50/H100/H200/HLW-P50 models have 
a strong, double wall design, with 2” or more of injected polyurethane foam insulation, providing a minimum of an R15 insulation value, one of the highest 
in the industry.  

The hinged bowl is designed to lift up for easy cleaning, as well as quick access to all internal components.  Stainless steel bowl construction ensures long 
life, and eliminates the risk of chipping paint and rust contamination. 

Canarm heated livestock waterers come with a 190 watt (P25), a 300 watt (HL50/H50/P50), 500 watt (H100/P100) or a 800 watt (H200 unit has 1 - 320 
watt + 1 - 500 watt) thermostatically controlled heating element.  An external pilot light (not available on P25, P50 or P100) turns on when the thermostat 
setting is reached - but it is not directly indicating the heating element has turned on. The thermostat is adjustable and can be accessed though the control 
cover.

The non-siphoning design and nylon control valve and float are designed for trouble free operation in all seasons.

IMPORTANT SAFETY INSTRUCTIONS

When using the electrical equipment, basic safety precautions should always be followed, including the following:
(a) 

READ AND FOLLOW ALL INSTURUCTIONS

(b) A green terminal (or a wire connector marked “G”, “GR”, “GROUND” or “GROUNDING”) is provided within the control box.  To reduce the risk of electric 
shock, connect this terminal or connector to the grounding terminal of the electric service or supply panel with a continuous copper wire in accordance 
with the Canadian Electrical code, Part 1.
(c) This product shall be protected by a Class A ground fault circuit interrupter.
(d) 

SAVE THESE INSTRUCTIONS 

.

INSTALLATION 

ATTENTION:  Electrical installation and maintenance MUST be performed by a qualified technician!  

Locating the Waterer:  (DIAGRAM 1.)

The waterer can be located indoors or out, and can be positioned on the fence line to supply water to two pens or positioned centrally in the pen to water 
larger numbers of animals.  When locating the waterer on a fence line the rails above the waterer should be removable to permit the unique easy cleaning 
feature to operate.  The waterer is equipped with a hinged bowl for easy cleaning, just swing the bowl up to dump the dirty water.  This also provides quick 
access and more space for installation and maintenance procedures.

Mounting the Waterer:

The waterer should be mounted on a 6' x 6'x 6" thick concrete base with a 3" thick raised concrete pad.  Bolts can be positioned in the concrete or drilling 
and concrete anchors can be used after the concrete has cured.  Place the waterer in position and secure with the brackets provided.  The brackets bolt 
to the side of the waterer in the weld nuts located near each corner.
(

NOTE:

 Poly models have molded corners on the inside of the housing.  Drill concrete anchors through the pilot holes provided).

Automatic Heated Livestock Waterers

Instruction Manual 

M0003 - 03/18                                                                                                                                                                          Page 2 of 5           

A

B

C

D

MODEL     A  

D

HL50           

24” 30”  18-1/8” 

25”

H50             

24” 30”  18-1/8” 

25”

H100           

24” 30”  23-3/8”  29-1/4”

H200           

24” 30”  25-1/8”  39-7/8”

HLW-P25      

24” 24” 

INTERNAL

 

INTERNAL

HLW-P50      

24” 30” 

INTERNAL

 

INTERNAL

HLW-P100    

28” 36” 

INTERNAL

 

INTERNAL

 REMOVABLE

VALVE COVER    

                                                              

Summary of Contents for HLW-HL50-09

Page 1: ...anty applies to the original purchaser user only it is null and void in case of alteration accident abuse neglect and operation not in accordance with instructions NOTICE No warranty claims will be ho...

Page 2: ...marked G GR GROUND or GROUNDING is provided within the control box To reduce the risk of electric shock connect this terminal or connector to the grounding terminal of the electric service or supply p...

Page 3: ...ed that each waterer be connected through a dedicated supply line to prevent stray voltage from other equipment on nondedicated lines Connections should be made to a 120 volt supply A ground fault int...

Page 4: ...ss Nut supplied in kit Step 2 Screw on P4876 Brass elbow onto P4875 Brass fitting oriented towards or into Bowl Ensure Teflon tape is applied to threads Step 3 Screw on the P4300 Plastic Valve to the...

Page 5: ...es Models H0 G4920 H100R and H0 G4920 H50R CANARM LTD CANARM LTEE ARTHUR MANUFACTURING FACILITY 2157 PARKEDALE AVE PO BOX 367 2555 RUE BERNARD LEFEBVRE 7686 CONCESSION 16 RR4 BROCKVILLE ONTARIO K6V 5V...

Page 6: ...antie s applique l acheteur original seulement elle est nulle dans lecas d alt rations d accident d abus de n gligence et lors d une op ration qui n est pas conforme aux instructions AVIS Aucune r cla...

Page 7: ...produit sera prot g par un interrupteur de circuit de mise terre par d faut de Classe A d Conservez ces instructions INSTALLATION Emplacement de l abreuvoir DIAGRAMME 1 L abreuvoir peut tre install l...

Page 8: ...s connexions lectriques doivent tre effectu es par un lectricien qualifi selon les normes locales Il est recommand que chaque abreuvoir soit branch sur une ligne d di e afin de pr venir un voltage dis...

Page 9: ...DE COURANT COURANT LUMI RE LUMI RE T MOIN T MOIN PAS UTILIS SUR LES PAS UTILIS SUR LES MOD LES P25 P50 MOD LES P25 P50 OU P100 OU P100 PAS UTILIS SUR LES PAS UTILIS SUR LES MOD LES P25 P50 MOD LES P2...

Page 10: ...H0 G4958 H200 MOD LE H200 TUYAU FLEXIBLE H0523 COUDE EN LAITON H0 P4836 4 BALLE EN PLASTIQUE H0 P4300 H0 P4305HF MOD LE H200 ASSAMBLAGE DU VALVE VIENS AVEC BRAS EN STAINLESS H0519 TUYAU BRACKET H0 G4...

Reviews: