pg. 8
There are several different wiring combinations that can be used in controlling
your ceilingfan to meet your specific requirements. Should the following method
not meet your requirements call or visit your nearest Canarm distributor for a full
list of fan accessories.
4. ELECTRICAL HOOKUP
INSTALLATION
NOTE: Once ground wires are connected, carefully tuck wires and marrette into
the metal outlet box making sure that the wires are clear of the hemisphere and
downrod when positioning in the mounting bracket.
pg. 7
• obtain fan and place hemisphere of downrod into mounting bracket
• rotate fan until the slot in the hemisphere locks into the tab of the
mounting bracket
• place looped end of safety cable over the wood screw and flat washer
not previously tightened (in Step 3)
• tighten above wood screw securing the safety cable
3. HOOKING UP SAFETY CABLE (DOWNROD MOUNT)
safety
cable
hemisphere
mounting
bracket
tab
slot
hemisphere
safety
cable
mounting
bracket
INSTALLATION
A. CONNECTING THE GROUND WIRE (GREEN)
CAUTION
GREEN wire - GROUND
BLACK wire (fan) - POWER
WHITE wire (fan) - COMMON
RED/BLUE wire (light kit) - POWER
See SAFETY PRECAUTIONS