GENERAL SAFETY

1.

All electrical work must be done in accordance with all applicable electrical codes by  a 
qualified electrician.

2.

Prior to wiring ensure the power supply is locked in the OFF position and that the motor 
nameplate voltage matches the supply voltage.

3.

Do not install or operate this fan in an environment where combustible materials, gases or 
fumes are present.

4. Caution:

the fan contains rotating parts and electrical service. Appropriate safety 

precautions should be taken during installation, operation and maintenance. 
When servicing the fan motor may be hot, allow time for cooling down.

5.

Before starting the unit, ensure the wheel rotates freely.

6.

Check and tighten where necessary all nuts, bolts & set screws prior to fan start up (as 
some may have loosened during shipment).

7. Please follow all applicable national, state/provincial and local codes, all of them will 

supersede this manual.

8. Failure to follow the safety instructions in this manual may cause serious injury or 

death due to electrical shock or high speed rotating parts.

The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures.

IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS
HANDLED BY QUALIFIED PERSONNEL.

Inspect all shipments carefully for damage. 

THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S BILL OF LADING AND FILE A

CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.

DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR. PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS.

DIMENSION & COMPONENT

ALX-M-07_31_14

Page 1 of 5

A

B

D

E

C

G

F

A

B

D

E

C

G

F

UPBLAST 

MODELS

DOWNBLAST 

MODELS

DOWNBLAST 

UPBLAST

Downblast Direct
Drive Shown

Note: Belt drive units are weighted without motor & drives.

Upblast Belt 
Drive Shown

Motor plate detail varies
on different sizes

Model

A

B

C

D

E

F

G Ø

Wheel

Diameter

Roof 

Opening

Net 

Weight

(lbs)

ALX105-UD

17.63

25.00

19.00 13.00 1.50

3.50

0.38

10.50

15.00

35

ALX120-UD

18.63

25.00

19.00 13.00 1.50

3.50

0.38

12.25

15.00

37

ALX135-UD/UB

22.25 / 25.25

32.13

21.00 17.13 1.50

3.75

0.44

13.50

17.00

53 / 62 

ALX150-UD/UB

23.13 / 26.13

32.13

21.00 17.13 1.50

3.75

0.44

15.00

17.00

58 / 67

ALX165-UD/UB

27.13 / 31.13

37.50

24.75 21.13 2.00

4.00

0.44

16.50

20.75

100 /108 

ALX180-UD/UB

27.75 / 31.75

37.50

24.75 21.13 2.00

4.00

0.44

18.25

20.75

108 / 116

ALX210-UB

36.25

43.75

33.13 25.50 2.50

4.00

0.44

21.25

29.00

178

ALX245-UB

37.00

43.75

33.13 25.50 2.50

4.00

0.44

24.50

29.00

183

Dimensions (inches)

Model

A

B

C

D

E

F

G Ø

Wheel

Diameter

Roof 

Opening

Net 

Weight 

(lbs)

ALX105-DD

18.00

25.00

19.00

2.50

1.50

3.50

0.38

10.50

15.00

33

ALX120-DD

19.00

25.00

19.00

3.50

1.50

3.50

0.38

12.25

15.00

35

ALX135-DD/DB

22.25 / 25.25

31.25

21.00

3.13

2.00

3.75

0.44

13.50

17.00

51 / 59

ALX150-DD/DB

23.13 / 26.13

31.25

21.00

3.75

2.00

3.75

0.44

15.00

17.00

56 / 65

ALX165-DD/DB

27.13 / 31.13

36.25

24.75

5.00

2.00

4.00

0.44

16.50

20.75

100 / 106

ALX180-DD/DB

27.75 / 31.75

36.25

24.75

5.50

2.00

4.00

0.44

18.25

20.75

104 / 110

ALX210-DB

36.25

43.75

33.13

5.25

2.50

4.00

0.44

21.25

29.00

176

ALX245-DB

37.00

43.75

33.13

5.88

2.50

4.00

0.44

24.50

29.00

181

Dimensions (inches)

Summary of Contents for ALX SERIES

Page 1: ...CEIVER MUST NOTE ANY DAMAGE ON THE CARRIER S BILL OF LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS...

Page 2: ...nd on the control box itself 4 Motor RPM range would be from full RPM to the RPM just set The lowest minimum voltage that may be applied to the motors is 65VAC Running at lower voltage can cause prema...

Page 3: ...sconnect switches are available for purchase as accessories No dampers can be used in the system UL762 RESTAURANT EXHAUST APPLICATION 1 Lock out all power sources 2 Inspect all fasteners and set screw...

Page 4: ...ong wheel rotation Re wire the motor to change direction of rotation Improper Duct System Check obstruction of duct in the duct or dirty filter Fan does not operate Reduced airflow Excessive noise vib...

Page 5: ...IBRATION ELIMINATOR 4 5 TOP PLATE 1 6 UPBLAST APRON 1 7 VENT 1 8 VERTICAL BRACKET 4 9 INLET BAFFLE 4 10 DRAIN 4 11 MOTOR SUPPORT RAIL 2 12 HORIZONTAL BRACKET 4 13 BASE 1 14 BLOWER WHEEL 1 5 6 7 3 2 8...

Page 6: ...a aucun dommage SI VOUS CONSTATEZ DES DOMMAGES VOUS DEVEZ LES NOTER SUR LE CONNAISSEMENT DU TRANSPORTEUR ET FAIRE UNE R CLAMATION AU TRANSPORTEUR IMM DIATEMENT NE SOULEVEZ PAS L QUIPEMENT PAR LE CAPOT...

Page 7: ...est 65VAC Un voltage en de de ce niveau peut causer un d faillance pr matur e du moteur Pour un moteur 3 phases un entra nement fr quence varaible VFD est requis pour ajuster la vitesse du moteur CON...

Page 8: ...alignement et la tension si applicable 4 Con rmer que le voltage utilis est identique celui du moteur et que le tout est bien c bl 5 Faire la rotation de la roue pour s assurer que ni la pale ni la c...

Page 9: ...et v rifier l op ration du volet contr l Mauvaise rotation de la roue Refaire le c blage pour changer la direction de la rotation Syst me de conduit inad quat Redimensionner le conduit Bruit vibration...

Page 10: ...D BIT VERS LE HAUT 1 7 VENT 1 8 FERRURE VERTICALE 4 9 D FLECTEUR D ENTR E 4 10 DRAIN 4 11 RAIL DE SOUTIEN DU MOTEUR 2 12 FERRURE HORIZONTALE 4 13 BASE 1 14 ROUE DE VENTILATEUR 1 5 6 7 3 2 8 9 4 14 11...