Canam Technology, Inc. MARK-IV User Manual Download Page 8

 

 

 

 

 
 
 
CANAM TECHNOLOGY, INC. (CTI) 
MARK-IV UHF NARROWBAND SIGNAL BOOSTER 

 

                                      USER’S MANUAL 

 

 

Page 8 of 12  

Rev0 May/2011 

 

Configure PC computer IP address as 192.168.100.X (X is a 
value between 0-255) with Network Mask = 255.255.255.0. 

 

Default gateway can be same value as IP address. 

o

 

Select “Obtain DNS server address automatically”. 

 

4.

 

Open a web browser and access the equipment by typing, in the 
address bar, the IP address of the equipment (

http://192.168.100.80

)

 

o

 

Login with username = operator, password = operator. 

 

B.1.2  Connect D.U.T to local area network 

 

 

Figure 5 - D.U.T. connected into local area network. 

 

The following steps are necessary to connect D.UT to LAN: 
 

 

1.

 

Find out the subnet the PC computer is currently plugged into. 

2.

 

Configure  D.U.T  IP  address  avoiding  conflict  with  other  devices  IP 
addresses. Use procedure in previous section B.1.1. 

 
Please  refer  to  UHF  Narrow  band  Signal  Booster  O&M  Manual  for  more 
details. 

Summary of Contents for MARK-IV

Page 1: ...MARK IV UHF NARROWBAND SIGNAL BOOSTER USER S MANUAL REVISION 0 SUBMITTED BY CANAM TECHNOLOGY INC May 2011...

Page 2: ...ble 7 B 1 2 Connect D U T to local area network 8 B 2 Using and setting up D U T 9 Section C RF Connections 11 C 1 Connecting the RF Out Port 11 C 2 Connecting the RF In Port 11 I II I T TA AB BL LE E...

Page 3: ...or more programmable frequency narrowband filters The desired operation frequencies must be configured using built in Web Server Programmable Individual Rx Threshold level Squelch per filter allows t...

Page 4: ...es shown by the Web Server are the following Main Status depicts status alarm indicators and meters Main Settings is used to configure system level macro settings Filter Settings contains the settings...

Page 5: ...ows the visual status that the D U T front panel has A brief explanation is given in Table 1 2 3 1 4 5 6 7 Figure 2 Front Panel details Table 1 Front Panel details Item Description 1 Intake fan 1 2 LC...

Page 6: ...connector is given in Table 2 2 1 4 6 7 3 5 8 9 10 11 12 13 Figure 3 Rear Panel details Table 2 Rear Panel details Item Description 1 Antenna Rx Input 2 NOT USED 3 NOT USED 4 AUX Digital I O Connecto...

Page 7: ...ble for connect equipment directly to a PC computer LAN port refer to Item 8 in Figure 3 2 The IP address of the equipment is shown in the LCD display By default it is 192 168 100 80 with Network Mask...

Page 8: ...equipment by typing in the address bar the IP address of the equipment http 192 168 100 80 o Login with username operator password operator B 1 2 Connect D U T to local area network Figure 5 D U T con...

Page 9: ...encies following filters distribution in Table 3 Table 3 Frequency ranges for filters Frequency Range MHz Assigned Filter Number Low end 450 470 1 and 2 Mid range 470 490 3 and 4 High end 490 512 5 an...

Page 10: ...ROWBAND SIGNAL BOOSTER USER S MANUAL Page 10 of 12 Rev0 May 2011 3 Go to Main Settings page o Verify the Maximum Desired Output Level per Filter is 27dBm o Uncheck Output MCPA Mute to enable MCPA outp...

Page 11: ...e to connect the test instrument to D U T RF Tx Output Port refer to Item 7 in Figure 3 C 2 Connecting the RF In Port 1 Adjust the RF Generator output power to 60 dBm 2 Adjust the RF Generator frequen...

Page 12: ...CANAM TECHNOLOGY INC CTI MARK IV UHF NARROWBAND SIGNAL BOOSTER USER S MANUAL Page 12 of 12 Rev0 May 2011 this page intentionally left blank...

Reviews: